Worked example
Example: Seawater train 30 C, 62/60 bar, 38,000/250 mg/L, 45 %, standard 32,000 mg/L, 55 bar, 1 bar drop, 50 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Permeate flow (actual) | 12,000 m³/d |
| Feed pressure (actual) | 62.000 bar |
| Concentrate pressure (actual) | 60.000 bar |
| Permeate pressure (actual) | 1.0000 bar |
| Feed TDS (actual) | 38,000 mg/L |
| Permeate TDS (actual) | 250.00 mg/L |
| Recovery (actual) | 45.000 % |
| Water temperature (actual) | 30.000 °C |
| Standard temperature | 25.000 °C |
| Standard feed pressure | 55.000 bar |
| Standard permeate pressure | 0 bar |
| Standard feed-to-concentrate pressure drop | 1.0000 bar |
| Standard feed TDS | 32,000 mg/L |
| Standard permeate TDS | 200.00 mg/L |
| Standard recovery | 50.000 % |
| Ions per formula unit (NaCl 2) | 2.0000 - |
| Molar mass of the salt (NaCl 58.44) | 58.440 kg/kmol |
Applying the formula below gives:
| Result | Value |
|---|---|
| Temperature correction factor | 0.86261 |
| Mean feed-concentrate TDS (actual) | 50,484 mg/L |
| Feed-concentrate osmotic pressure (actual) | 43.548 bar |
| Net driving pressure (actual) | 16.668 bar |
| Net driving pressure (standard) | 17.034 bar |
| Normalised permeate flow | 10,579 m³/d |
| Salt passage (actual) | 0.65789 % |
| Normalised salt passage | 0.67173 % |
Open this example in the calculator and change any input.
Formula
\(TCF = 1.03^{(T_s - T)}, \quad C_{FC} = C_F\frac{\ln[1/(1 - r)]}{r}, \quad \pi = iCRT\)
\(NDP = \frac{P_F + P_C}{2} - P_P - (\pi_{FC} - \pi_P), \quad Q_{p,s} = Q_p\,TCF\frac{NDP_s}{NDP}\)
\(SP_s = SP\frac{NDP}{NDP_s}\frac{C_{FC,s}/C_{F,s}}{C_{FC}/C_F}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_p\) | Permeate flow (actual) | m³/s |
| \(P_F\) | Feed pressure (actual) | Pa |
| \(P_C\) | Concentrate pressure (actual) | Pa |
| \(P_P\) | Permeate pressure (actual) | Pa |
| \(C_F\) | Feed TDS (actual) | kg/m³ |
| \(C_P\) | Permeate TDS (actual) | kg/m³ |
| \(r\) | Recovery (actual) | - |
| \(T\) | Water temperature (actual) | K |
| \(T_s\) | Standard temperature | K |
| \(P_{F,s}\) | Standard feed pressure | Pa |
| \(P_{P,s}\) | Standard permeate pressure | Pa |
| \(\Delta P_s\) | Standard feed-to-concentrate pressure drop | Pa |
| \(C_{F,s}\) | Standard feed TDS | kg/m³ |
| \(C_{P,s}\) | Standard permeate TDS | kg/m³ |
| \(r_s\) | Standard recovery | - |
| \(i\) | Ions per formula unit (NaCl 2) | - |
| \(M\) | Molar mass of the salt (NaCl 58.44) | kg/kmol |
| \(TCF\) | Temperature correction factor | - |
| \(C_{FC}\) | Mean feed-concentrate TDS (actual) | kg/m³ |
| \(\pi_{FC}\) | Feed-concentrate osmotic pressure (actual) | Pa |
| \(NDP\) | Net driving pressure (actual) | Pa |
| \(NDP_s\) | Net driving pressure (standard) | Pa |
| \(Q_{p,s}\) | Normalised permeate flow | m³/s |
| \(SP\) | Salt passage (actual) | - |
| \(SP_s\) | Normalised salt passage | - |
Method and standards
Standardisation of RO operating data.
Where it is used
- Plant performance trending and cleaning decisions.
- Warranty discussions with membrane suppliers.
Common mistakes
- Comparing raw permeate flow across seasons.
- Using feed pressure alone instead of NDP.
Assumptions and limits
- Van 't Hoff osmotic pressure (dilute, single salt); temperature correction 3 % per °C.
Questions and answers
Why normalise?
Permeate flow changes with temperature, pressure and feed salinity; normalising removes these so the trend shows only fouling, scaling or membrane damage.
What are the standard conditions?
Usually the manufacturer's test conditions or the plant's start-up data; consistency matters more than the choice.
What do the defaults represent?
An illustrative case: Seawater train 30 C, 62/60 bar, 38,000/250 mg/L, 45 %, standard 32,000 mg/L, 55 bar, 1 bar drop, 50 %. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 17-5, eqs. 17-7, 17-17, 17-20, 17-22, 17-24 and 17-25 and Example 17-2