FireCADCalc

Reverse Osmosis Data Normalisation: Standard Flow and Salt Passage

Normalises RO permeate flow and salt passage to standard conditions with the temperature correction, net driving pressure and feed-concentrate osmotic pressure.

Inputs

Examples: Seawater train 30 C, 62/60 bar, 38,000/250 mg/L, 45 %, standard 32,000 mg/L, 55 bar, 1 bar drop, 50 %

Accepted: 0.0864 to 8,640,000 m³/d
Accepted: 0.1 to 120 bar
Accepted: 0.1 to 120 bar
Accepted: 0 to 10 bar
Accepted: 10 to 60,000 mg/L
Accepted: 0.01 to 5,000 mg/L
Accepted: 5 to 95 %
Accepted: 0 to 45 °C
Accepted: 0 to 45 °C
Accepted: 0.1 to 120 bar
Accepted: 0 to 10 bar
Accepted: 0 to 10 bar
Accepted: 10 to 60,000 mg/L
Accepted: 0.01 to 5,000 mg/L
Accepted: 5 to 95 %
Accepted: 1 to 5
Accepted: 10 to 500 kg/kmol

Results

Pressures are gauge. Osmotic pressure by van 't Hoff with full dissociation; the feed-concentrate concentration is the log-mean C_F ln[1/(1 − r)]/r. A drop of 10–15 % in normalised flow or a rise in normalised salt passage signals cleaning.

Temperature correction factor0.86261
Mean feed-concentrate TDS (actual)50,484mg/L
Feed-concentrate osmotic pressure (actual)43.548bar
Net driving pressure (actual)16.668bar
Net driving pressure (standard)17.034bar
Normalised permeate flow10,579m³/d
Salt passage (actual)0.65789%
Normalised salt passage0.67173%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Seawater train 30 C, 62/60 bar, 38,000/250 mg/L, 45 %, standard 32,000 mg/L, 55 bar, 1 bar drop, 50 %. The inputs, in the units selected above:

InputValue
Permeate flow (actual)12,000 m³/d
Feed pressure (actual)62.000 bar
Concentrate pressure (actual)60.000 bar
Permeate pressure (actual)1.0000 bar
Feed TDS (actual)38,000 mg/L
Permeate TDS (actual)250.00 mg/L
Recovery (actual)45.000 %
Water temperature (actual)30.000 °C
Standard temperature25.000 °C
Standard feed pressure55.000 bar
Standard permeate pressure0 bar
Standard feed-to-concentrate pressure drop1.0000 bar
Standard feed TDS32,000 mg/L
Standard permeate TDS200.00 mg/L
Standard recovery50.000 %
Ions per formula unit (NaCl 2)2.0000 -
Molar mass of the salt (NaCl 58.44)58.440 kg/kmol

Applying the formula below gives:

ResultValue
Temperature correction factor0.86261
Mean feed-concentrate TDS (actual)50,484 mg/L
Feed-concentrate osmotic pressure (actual)43.548 bar
Net driving pressure (actual)16.668 bar
Net driving pressure (standard)17.034 bar
Normalised permeate flow10,579 m³/d
Salt passage (actual)0.65789 %
Normalised salt passage0.67173 %

Open this example in the calculator and change any input.

Formula

\(TCF = 1.03^{(T_s - T)}, \quad C_{FC} = C_F\frac{\ln[1/(1 - r)]}{r}, \quad \pi = iCRT\)

\(NDP = \frac{P_F + P_C}{2} - P_P - (\pi_{FC} - \pi_P), \quad Q_{p,s} = Q_p\,TCF\frac{NDP_s}{NDP}\)

\(SP_s = SP\frac{NDP}{NDP_s}\frac{C_{FC,s}/C_{F,s}}{C_{FC}/C_F}\)

Variables

Symbol Meaning SI unit
\(Q_p\) Permeate flow (actual) m³/s
\(P_F\) Feed pressure (actual) Pa
\(P_C\) Concentrate pressure (actual) Pa
\(P_P\) Permeate pressure (actual) Pa
\(C_F\) Feed TDS (actual) kg/m³
\(C_P\) Permeate TDS (actual) kg/m³
\(r\) Recovery (actual) -
\(T\) Water temperature (actual) K
\(T_s\) Standard temperature K
\(P_{F,s}\) Standard feed pressure Pa
\(P_{P,s}\) Standard permeate pressure Pa
\(\Delta P_s\) Standard feed-to-concentrate pressure drop Pa
\(C_{F,s}\) Standard feed TDS kg/m³
\(C_{P,s}\) Standard permeate TDS kg/m³
\(r_s\) Standard recovery -
\(i\) Ions per formula unit (NaCl 2) -
\(M\) Molar mass of the salt (NaCl 58.44) kg/kmol
\(TCF\) Temperature correction factor -
\(C_{FC}\) Mean feed-concentrate TDS (actual) kg/m³
\(\pi_{FC}\) Feed-concentrate osmotic pressure (actual) Pa
\(NDP\) Net driving pressure (actual) Pa
\(NDP_s\) Net driving pressure (standard) Pa
\(Q_{p,s}\) Normalised permeate flow m³/s
\(SP\) Salt passage (actual) -
\(SP_s\) Normalised salt passage -

Method and standards

Standardisation of RO operating data.

Where it is used

  • Plant performance trending and cleaning decisions.
  • Warranty discussions with membrane suppliers.

Common mistakes

  • Comparing raw permeate flow across seasons.
  • Using feed pressure alone instead of NDP.

Assumptions and limits

  • Van 't Hoff osmotic pressure (dilute, single salt); temperature correction 3 % per °C.

Questions and answers

Why normalise?

Permeate flow changes with temperature, pressure and feed salinity; normalising removes these so the trend shows only fouling, scaling or membrane damage.

What are the standard conditions?

Usually the manufacturer's test conditions or the plant's start-up data; consistency matters more than the choice.

What do the defaults represent?

An illustrative case: Seawater train 30 C, 62/60 bar, 38,000/250 mg/L, 45 %, standard 32,000 mg/L, 55 bar, 1 bar drop, 50 %. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 17-5, eqs. 17-7, 17-17, 17-20, 17-22, 17-24 and 17-25 and Example 17-2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.