Worked example
Example: Conventional 7.5 m/h, 36 h, 15 min to waste, 55 m/h for 10 min, 30 min down; 20,000 m3/d, 40 m2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Filtration rate | 7.5000 m/h |
| Filter run length | 36.000 h |
| Filter-to-waste time | 15.000 min |
| Backwash rate | 55.000 m/h |
| Backwash duration | 10.000 min |
| Other out-of-service time per cycle (draining, refilling) | 30.000 min |
| Net plant flow to produce | 20,000 m³/d |
| Area of one filter | 40.000 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Unit filter run volume | 270.00 m |
| Unit backwash volume | 9.1667 m |
| Unit filter-to-waste volume | 1.8750 m |
| Filter recovery | 95.910 % |
| Net production rate averaged over the cycle | 7.0625 m/h |
| Filter area needed in service | 117.99 m² |
| Filters needed, plus one out of service | 4.0000 |
Open this example in the calculator and change any input.
Formula
\(UFRV = vt_r, \quad UBWV = v_{bw}t_{bw}, \quad UFWV = vt_{fw}, \quad r = \frac{UFRV - UBWV - UFWV}{UFRV}\)
\(v_{net} = \frac{UFRV - UBWV - UFWV}{t_r + t_{bw} + t_{down}}, \quad A = \frac{Q}{v_{net}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(v\) | Filtration rate | m/s |
| \(t_r\) | Filter run length | s |
| \(t_{fw}\) | Filter-to-waste time | s |
| \(v_{bw}\) | Backwash rate | m/s |
| \(t_{bw}\) | Backwash duration | s |
| \(t_{down}\) | Other out-of-service time per cycle (draining, refilling) | s |
| \(Q\) | Net plant flow to produce | m³/s |
| \(A_f\) | Area of one filter | m² |
| \(UFRV\) | Unit filter run volume | m |
| \(UBWV\) | Unit backwash volume | m |
| \(UFWV\) | Unit filter-to-waste volume | m |
| \(r\) | Filter recovery | - |
| \(v_{net}\) | Net production rate averaged over the cycle | m/s |
| \(A\) | Filter area needed in service | m² |
| \(n\) | Filters needed, plus one out of service | - |
Method and standards
Filter water balance per unit area.
Where it is used
- Sizing filter galleries.
- Comparing filter performance and backwash practice.
Common mistakes
- Counting backwash water as production.
- Forgetting the filter out of service.
Assumptions and limits
- Steady cycle; equal filters.
Questions and answers
Why use UFRV?
It is the water produced per square metre per run; dividing backwash volume by it gives the waste fraction directly, independent of filter size.
Why add a filter out of service?
One filter is always backwashing or under maintenance, so the rest must carry the plant flow.
What do the defaults represent?
An illustrative case: Conventional 7.5 m/h, 36 h, 15 min to waste, 55 m/h for 10 min, 30 min down; 20,000 m3/d, 40 m2. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 11-7, eqs. 11-66 to 11-69 and Example 11-8