Rapid Filter Run Volumes, Recovery and Required Filter Area

Unit filter run, backwash and filter-to-waste volumes, recovery, net production rate and the filter area for a plant flow with one filter out of service.

Inputs

Examples: Conventional 7.5 m/h, 36 h, 15 min to waste, 55 m/h for 10 min, 30 min down; 20,000 m3/d, 40 m2Short runs 10 m/h for 12 h, backwash 50 m/h for 12 min; 10,000 m3/d, 25 m2

Accepted: 0.36 to 72 m/h
Accepted: 1 to 277.78 h
Accepted: 0 to 120 min
Accepted: 3.6 to 180 m/h
Accepted: 1 to 120 min
Accepted: 0 to 600 min
Accepted: 8.64 to 8,640,000 m³/d
Accepted: 1 to 500 m²

Results

Filter-to-waste time is part of the run; backwash and other down time are not. Recovery above 95 % is the usual target; a UFRV below about 200 m³/m² is poor.

Unit filter run volume270.00m
Unit backwash volume9.1667m
Unit filter-to-waste volume1.8750m
Filter recovery95.910%
Net production rate averaged over the cycle7.0625m/h
Filter area needed in service117.99m²
Filters needed, plus one out of service4.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Conventional 7.5 m/h, 36 h, 15 min to waste, 55 m/h for 10 min, 30 min down; 20,000 m3/d, 40 m2. The inputs, in the units selected above:

InputValue
Filtration rate7.5000 m/h
Filter run length36.000 h
Filter-to-waste time15.000 min
Backwash rate55.000 m/h
Backwash duration10.000 min
Other out-of-service time per cycle (draining, refilling)30.000 min
Net plant flow to produce20,000 m³/d
Area of one filter40.000 m²

Applying the formula below gives:

ResultValue
Unit filter run volume270.00 m
Unit backwash volume9.1667 m
Unit filter-to-waste volume1.8750 m
Filter recovery95.910 %
Net production rate averaged over the cycle7.0625 m/h
Filter area needed in service117.99 m²
Filters needed, plus one out of service4.0000

Open this example in the calculator and change any input.

Formula

\(UFRV = vt_r, \quad UBWV = v_{bw}t_{bw}, \quad UFWV = vt_{fw}, \quad r = \frac{UFRV - UBWV - UFWV}{UFRV}\)

\(v_{net} = \frac{UFRV - UBWV - UFWV}{t_r + t_{bw} + t_{down}}, \quad A = \frac{Q}{v_{net}}\)

Variables

Symbol Meaning SI unit
\(v\) Filtration rate m/s
\(t_r\) Filter run length s
\(t_{fw}\) Filter-to-waste time s
\(v_{bw}\) Backwash rate m/s
\(t_{bw}\) Backwash duration s
\(t_{down}\) Other out-of-service time per cycle (draining, refilling) s
\(Q\) Net plant flow to produce m³/s
\(A_f\) Area of one filter m²
\(UFRV\) Unit filter run volume m
\(UBWV\) Unit backwash volume m
\(UFWV\) Unit filter-to-waste volume m
\(r\) Filter recovery -
\(v_{net}\) Net production rate averaged over the cycle m/s
\(A\) Filter area needed in service m²
\(n\) Filters needed, plus one out of service -

Method and standards

Filter water balance per unit area.

Where it is used

  • Sizing filter galleries.
  • Comparing filter performance and backwash practice.

Common mistakes

  • Counting backwash water as production.
  • Forgetting the filter out of service.

Assumptions and limits

  • Steady cycle; equal filters.

Questions and answers

Why use UFRV?

It is the water produced per square metre per run; dividing backwash volume by it gives the waste fraction directly, independent of filter size.

Why add a filter out of service?

One filter is always backwashing or under maintenance, so the rest must carry the plant flow.

What do the defaults represent?

An illustrative case: Conventional 7.5 m/h, 36 h, 15 min to waste, 55 m/h for 10 min, 30 min down; 20,000 m3/d, 40 m2. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 11-7, eqs. 11-66 to 11-69 and Example 11-8

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.