Worked example
Example: Third stage of the same train at G 40. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Plant flow | 75,000 m³/d |
| Parallel trains | 4.0000 - |
| Stages in series per train | 4.0000 - |
| Total flocculation time | 20.000 min |
| Velocity gradient in this stage | 40.000 1/s |
| Impeller diameter (about 0.45 of the equivalent tank diameter) | 2.0000 m |
| Impeller power number (pitched foil 0.2–0.3, pitched blade 1.3) | 0.25000 - |
| Impeller pumping number (foil about 0.5) | 0.50000 - |
| Water dynamic viscosity (10 °C 1.31 mPa·s, 20 °C 1.00) | 1.3100 mPa·s |
| Water density | 999.70 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Stage volume | 65.104 m³ |
| Side of a cubic stage | 4.0229 m |
| Equivalent tank diameter | 4.5393 m |
| Suggested impeller diameter | 2.0427 m |
| Water power | 136.46 W |
| Impeller speed | 15.447 rpm |
| Tip speed | 1.6176 m/s |
| Impeller pumping rate | 1.0298 m³/s |
| Circulation time | 63.222 s |
| Gt for this stage | 12,000 |
Open this example in the calculator and change any input.
Formula
\(P = G^2\mu V, \quad N = \left(\frac{P}{N_p\rho D^5}\right)^{1/3}\)
\(Q_p = N_QND^3, \quad t_c = \frac{V}{Q_p}, \quad T_e = \sqrt{\frac{4A_{plan}}{\pi}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Plant flow | m³/s |
| \(n_t\) | Parallel trains | - |
| \(n_s\) | Stages in series per train | - |
| \(t\) | Total flocculation time | s |
| \(G\) | Velocity gradient in this stage | 1/s |
| \(D\) | Impeller diameter (about 0.45 of the equivalent tank diameter) | m |
| \(N_p\) | Impeller power number (pitched foil 0.2–0.3, pitched blade 1.3) | - |
| \(N_Q\) | Impeller pumping number (foil about 0.5) | - |
| \(\mu\) | Water dynamic viscosity (10 °C 1.31 mPa·s, 20 °C 1.00) | Pa·s |
| \(\rho\) | Water density | kg/m³ |
| \(V\) | Stage volume | m³ |
| \(L\) | Side of a cubic stage | m |
| \(T_e\) | Equivalent tank diameter | m |
| \(0.45T_e\) | Suggested impeller diameter | m |
| \(P\) | Water power | W |
| \(N\) | Impeller speed | rad/s |
| \(v_{tip}\) | Tip speed | m/s |
| \(Q_p\) | Impeller pumping rate | m³/s |
| \(t_c\) | Circulation time | s |
| \(Gt\) | Gt for this stage | - |
Method and standards
Camp–Stein velocity gradient with the impeller power number relation.
Where it is used
- Sizing flocculator drives and choosing speeds.
- Checking existing flocculators against G and Gt guidance.
Common mistakes
- Using the motor rating as water power (gearbox and motor losses are extra).
- Using viscosity at 20 °C for a cold-water design.
Assumptions and limits
- Fully turbulent impeller (constant power number); the cubic stage is a sizing assumption.
Questions and answers
What is G?
Camp and Stein's root-mean-square velocity gradient, G = √(P/μV); it measures how hard the water is stirred and so how often particles collide.
Why taper G through the stages?
Large flocs break up at high shear; tapering lets them grow while keeping enough collisions.
What do the defaults represent?
An illustrative case: Third stage of the same train at G 40. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 9-7, eqs. 9-40 and 9-63, Table 9-13 and Example 9-8