Worked example
Example: UV/H2O2 for 1,4-dioxane: 60 kW, 50 L/s, 3 to 0.3 ug/L. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Lamp electrical power | 60.000 kW |
| Flow | 50.000 L/s |
| Influent concentration (any unit) | 3.0000 - |
| Effluent concentration (same unit) | 0.30000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Orders of magnitude removed | 1.0000 |
| Electrical energy per volume treated | 0.33333 kWh/m³ |
| Electrical energy per order | 0.33333 kWh/m³ |
| EE/O per 1,000 US gallons, kWh | 1.2618 |
Open this example in the calculator and change any input.
Formula
\(EE/O = \frac{P}{Q\log_{10}(C_i/C_f)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Lamp electrical power | W |
| \(Q\) | Flow | m³/s |
| \(C_i\) | Influent concentration (any unit) | - |
| \(C_f\) | Effluent concentration (same unit) | - |
| \(\log(C_i/C_f)\) | Orders of magnitude removed | - |
| \(E/V\) | Electrical energy per volume treated | J/m³ |
| \(EE/O\) | Electrical energy per order | J/m³ |
| \(EE/O_{US}\) | EE/O per 1,000 US gallons, kWh | - |
Method and standards
Electrical energy per order figure of merit (Bolton et al., 2001).
Where it is used
- Comparing UV and AOP vendor offers.
- Operating cost estimates for micropollutant destruction.
Common mistakes
- Using lamp UV output instead of electrical input.
- Applying EE/O at high concentrations where kinetics are not first order.
Assumptions and limits
- First-order destruction; electrical energy only.
Questions and answers
Why per order?
For first-order destruction each tenfold reduction costs the same energy, so EE/O compares reactors and waters fairly.
What raises EE/O?
UV absorbance of the water (low UVT), radical scavengers such as bicarbonate and NOM, and lamp ageing.
What do the defaults represent?
An illustrative case: UV/H2O2 for 1,4-dioxane: 60 kW, 50 L/s, 3 to 0.3 ug/L. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 8-6 and 18-5, Example 8-14 (Bolton et al., 2001)