Membrane Fouling Index (MFI) from Normalised Specific Flux

Membrane fouling index from two points of normalised specific flux against specific throughput, and the throughput and time until a cleaning trigger is reached.

Inputs

Examples: Pilot UF on surface water: 0.95 at 50 L/m2, 0.80 at 2000 L/m2, trigger 0.5, 80 L/(m2 h)

Accepted: 0 to 10,000,000 mm
Accepted: 1 to 150 %
Accepted: 0 to 10,000,000 mm
Accepted: 1 to 150 %
Accepted: 1 to 100 %
Accepted: 0.36 to 3,600 L/(m²·h)

Results

1/J′ = 1/J′₀ + MFI·V_sp, with J′ the specific flux (temperature- and pressure-corrected) divided by that of the new membrane. Using points from successive filter runs (start of each run) gives the hydraulically irreversible index; points within one run give the total index.

Membrane fouling index0.101211/m
Intercept of 1/J′ at zero throughput1.0476
Specific throughput when the trigger is reached (1 mm = 1 L/m²)9,410.0mm
Further throughput after point 2 (1 mm = 1 L/m²)7,410.0mm
Time to the trigger at the operating flux3.8594d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Pilot UF on surface water: 0.95 at 50 L/m2, 0.80 at 2000 L/m2, trigger 0.5, 80 L/(m2 h). The inputs, in the units selected above:

InputValue
Specific throughput at point 1 (1 mm = 1 L/m²)50.000 mm
Normalised specific flux at point 195.000 %
Specific throughput at point 2 (1 mm = 1 L/m²)2,000.0 mm
Normalised specific flux at point 280.000 %
Normalised specific flux that triggers cleaning50.000 %
Operating flux80.000 L/(m²·h)

Applying the formula below gives:

ResultValue
Membrane fouling index0.10121 1/m
Intercept of 1/J′ at zero throughput1.0476
Specific throughput when the trigger is reached (1 mm = 1 L/m²)9,410.0 mm
Further throughput after point 2 (1 mm = 1 L/m²)7,410.0 mm
Time to the trigger at the operating flux3.8594 d

Open this example in the calculator and change any input.

Formula

\(\frac{1}{J'_{sp}} = \frac{1}{J'_{sp,0}} + MFI\cdot V_{sp}, \quad MFI = \frac{1/J'_{sp,2} - 1/J'_{sp,1}}{V_{sp,2} - V_{sp,1}}\)

\(V_{sp,clean} = \frac{1/J'_{min} - 1/J'_{sp,0}}{MFI}, \quad t = \frac{V_{sp,clean} - V_{sp,2}}{J}\)

Variables

Symbol Meaning SI unit
\(V_{sp,1}\) Specific throughput at point 1 (1 mm = 1 L/m²) m
\(J'_{sp,1}\) Normalised specific flux at point 1 -
\(V_{sp,2}\) Specific throughput at point 2 (1 mm = 1 L/m²) m
\(J'_{sp,2}\) Normalised specific flux at point 2 -
\(J'_{min}\) Normalised specific flux that triggers cleaning -
\(J\) Operating flux m/s
\(MFI\) Membrane fouling index 1/m
\(1/J'_{sp,0}\) Intercept of 1/J′ at zero throughput -
\(V_{sp,clean}\) Specific throughput when the trigger is reached (1 mm = 1 L/m²) m
\(\Delta V_{sp}\) Further throughput after point 2 (1 mm = 1 L/m²) m
\(t\) Time to the trigger at the operating flux s

Method and standards

Resistance-in-series fouling model linear in specific throughput.

Where it is used

  • Comparing fouling of source waters and membranes.
  • Estimating clean-in-place intervals from pilot data.

Common mistakes

  • Using raw flux without temperature and pressure correction.
  • Mixing within-run and run-to-run points.

Assumptions and limits

  • Fouling resistance proportional to throughput.

Questions and answers

Why use specific throughput rather than time?

Throughput per unit area lets runs of different length, flux and scale be compared; fouling builds with the volume filtered.

What do the defaults represent?

An illustrative case: Pilot UF on surface water: 0.95 at 50 L/m2, 0.80 at 2000 L/m2, trigger 0.5, 80 L/(m2 h). Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 12-7, eqs. 12-21 to 12-25 and Example 12-6 (Huang et al. 2008)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.