Worked example
Example: TCE in a diffused aerator, kg/kl 150, H 0.42. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Oxygen KLa of the device | 0.003000 1/s |
| Liquid diffusivity of the compound | 9.1000e-10 m²/s |
| Liquid diffusivity of oxygen | 2.0600e-09 m²/s |
| Dimensionless Henry's constant of the compound | 0.42000 - |
| Gas to liquid film coefficient ratio (surface aerators 40–200) | 150.00 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Liquid-film scaling | 0.66464 |
| Liquid-film share of resistance | 98.438 % |
| Overall KLa of the compound | 0.001963 1/s |
| Time for 90 % removal in a batch | 19.552 min |
Open this example in the calculator and change any input.
Formula
\(K_La_{(c)} = K_{L,O_2}a\left(\frac{D_{l,c}}{D_{l,O_2}}\right)^{1/2}\left(1 + \frac{1}{Hk_g/k_l}\right)^{-1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(K_{L,O_2}a\) | Oxygen KLa of the device | 1/s |
| \(D_{l,c}\) | Liquid diffusivity of the compound | m²/s |
| \(D_{l,O_2}\) | Liquid diffusivity of oxygen | m²/s |
| \(H\) | Dimensionless Henry's constant of the compound | - |
| \(k_g/k_l\) | Gas to liquid film coefficient ratio (surface aerators 40–200) | - |
| \(\sqrt{D_c/D_{O_2}}\) | Liquid-film scaling | - |
| \((1 + 1/(Hk_g/k_l))^{-1}\) | Liquid-film share of resistance | - |
| \(K_La\) | Overall KLa of the compound | 1/s |
| \(t_{90}\) | Time for 90 % removal in a batch | s |
Method and standards
Two-film theory with penetration-theory scaling.
Where it is used
- VOC emissions from aeration basins.
- Stripping in diffused or surface aerators.
Common mistakes
- Ignoring gas-film resistance for low-H compounds.
- Using the 1/2 power on Henry's constant instead of the diffusivity.
Assumptions and limits
- Same device and hydrodynamics for both compounds.
Questions and answers
Why use oxygen as a reference?
Oxygen transfer is easy to measure (reaeration tests) and is liquid-film controlled, so its KLa transfers to other compounds by the diffusivity ratio.
When does the gas film matter?
When H k_g/k_l is small, typically for compounds with H below about 0.05; their transfer is slower than the diffusivity alone suggests.
What do the defaults represent?
An illustrative case: TCE in a diffused aerator, kg/kl 150, H 0.42. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 7-6, eq. 7-99 and Example 7-9