FireCADCalc

Granular Filter Particle Removal: Yao and Tufenkji–Elimelech Models

Single-collector contact efficiency by interception, sedimentation and diffusion (Yao and Tufenkji–Elimelech models) and the clean-bed particle removal.

Inputs

Examples: 1 um particles near the removal minimum, 0.6 mm sand, 10 m/hSlow sand filter: 0.2 um particles, 0.3 mm sand, 0.2 m/h, alpha 0.510 um silt particles (2650 kg/m3), 1 mm anthracite

Accepted: 0.001 to 100 µm
Accepted: 0.05 to 10 mm
Accepted: 0.036 to 72 m/h
Accepted: 0.01 to 5 m
Accepted: 20 to 80 %
Accepted: 0.1 to 100 %
Accepted: 500 to 5,000 kg/m³
Accepted: 950 to 1,050 kg/m³
Accepted: 0.2 to 2 mPa·s
Accepted: 0 to 60 °C
Accepted: 0.01 to 100

Results

Clean-bed removal ln(C/C₀) = −3(1 − ε)αηL/(2d_c) for monodisperse media; the attachment efficiency α depends on coagulation (near 1 when particles are well destabilised).

Relative size group d_p/d_c0.001667
Gravity number8.7726e-06
Peclet number4,493,246
Attraction number3.3565e-04
van der Waals number2.5136
Happel porosity function33.639
TE interception efficiency1.5120e-04
TE sedimentation efficiency2.6138e-06
TE diffusion efficiency2.3901e-04
Total single-collector efficiency, Tufenkji–Elimelech3.9282e-04
Total single-collector efficiency, Yao1.5984e-04
Clean-bed passing fraction, TE model65.234%
Log removal, TE model0.18553
Clean-bed passing fraction, Yao model84.044%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1 um particles near the removal minimum, 0.6 mm sand, 10 m/h. The inputs, in the units selected above:

InputValue
Particle diameter1.0000 µm
Filter grain (collector) diameter0.60000 mm
Filtration rate10.000 m/h
Bed depth0.75000 m
Bed porosity42.000 %
Attachment efficiency100.00 %
Particle density1,050.0 kg/m³
Water density999.10 kg/m³
Water viscosity1.1380 mPa·s
Water temperature15.000 °C
Hamaker constant, 10⁻²⁰ J1.0000 -

Applying the formula below gives:

ResultValue
Relative size group d_p/d_c0.001667
Gravity number8.7726e-06
Peclet number4,493,246
Attraction number3.3565e-04
van der Waals number2.5136
Happel porosity function33.639
TE interception efficiency1.5120e-04
TE sedimentation efficiency2.6138e-06
TE diffusion efficiency2.3901e-04
Total single-collector efficiency, Tufenkji–Elimelech3.9282e-04
Total single-collector efficiency, Yao1.5984e-04
Clean-bed passing fraction, TE model65.234 %
Log removal, TE model0.18553
Clean-bed passing fraction, Yao model84.044 %

Open this example in the calculator and change any input.

Formula

\(\eta_{TE} = 0.55A_SN_A^{1/8}N_R^{1.675} + 0.22N_R^{-0.24}N_{vdW}^{0.053}N_G^{1.11} + 2.4A_S^{1/3}N_R^{-0.081}N_{vdW}^{0.052}Pe^{-0.715}\)

\(\eta_{Yao} = \tfrac{3}{2}N_R^2 + N_G + 4Pe^{-2/3}, \quad \frac{C}{C_0} = \exp\left[-\frac{3(1 - \varepsilon)\alpha\eta L}{2d_c}\right]\)

Variables

Symbol Meaning SI unit
\(d_p\) Particle diameter m
\(d_c\) Filter grain (collector) diameter m
\(v_F\) Filtration rate m/s
\(L\) Bed depth m
\(\varepsilon\) Bed porosity -
\(\alpha\) Attachment efficiency -
\(\rho_p\) Particle density kg/m³
\(\rho_w\) Water density kg/m³
\(\mu\) Water viscosity Pa·s
\(T\) Water temperature K
\(H_a\) Hamaker constant, 10⁻²⁰ J -
\(N_R\) Relative size group d_p/d_c -
\(N_G\) Gravity number -
\(Pe\) Peclet number -
\(N_A\) Attraction number -
\(N_{vdW}\) van der Waals number -
\(A_S\) Happel porosity function -
\(\eta_I\) TE interception efficiency -
\(\eta_G\) TE sedimentation efficiency -
\(\eta_D\) TE diffusion efficiency -
\(\eta_{TE}\) Total single-collector efficiency, Tufenkji–Elimelech -
\(\eta_{Yao}\) Total single-collector efficiency, Yao -
\(C/C_0\) Clean-bed passing fraction, TE model -
\(LRV\) Log removal, TE model -
\(C/C_0\,(Yao)\) Clean-bed passing fraction, Yao model -

Method and standards

Colloid filtration theory with the Yao and Tufenkji–Elimelech correlations for single-collector efficiency.

Where it is used

  • Choosing filter media size.
  • Estimating virus and particle removal in rapid and slow sand filters.

Common mistakes

  • Mixing up the particle and media diameters.
  • Assuming α = 1 without proper coagulation.

Assumptions and limits

  • Clean bed, monodisperse media, favourable attachment.

Questions and answers

Why is removal worst for particles around 1 µm?

Small particles reach the grains by diffusion and large ones by interception and settling; around 1–2 µm neither mechanism is strong (the Yao minimum).

What do the defaults represent?

An illustrative case: 1 um particles near the removal minimum, 0.6 mm sand, 10 m/h. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 11-5, eqs. 11-36 to 11-54, Table 11-4 and Example 11-6 (Yao, Habibian and O'Melia 1971; Tufenkji and Elimelech 2004)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.