FireCADCalc

Adsorbent Internal Surface Area from Porosity and Pore Size

Pore volume and internal surface area of a porous adsorbent from particle porosity, particle density and pore diameter, taking cylindrical pores.

Inputs

Examples: Illustrative activated carbon: porosity 0.6, 800 kg/m3, 2 nm pores

Accepted: 5 to 90 %
Accepted: 100 to 3,000 kg/m³
Accepted: 0.3 to 1,000 nm

Results

Cylindrical pores: area 2πRH and volume πR²H per pore, so A/V = 2/R = 4/d. Real adsorbents have a spread of pore sizes; micropores (< 2 nm) carry most of the area.

Pore volume per mass0.75000L/kg
Surface-to-pore-volume ratio 4/d2.0000e+091/m
Internal surface area1,500.0m²/g

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative activated carbon: porosity 0.6, 800 kg/m3, 2 nm pores. The inputs, in the units selected above:

InputValue
Particle porosity (pore volume share)60.000 %
Particle (apparent) density800.00 kg/m³
Pore diameter2.0000 nm

Applying the formula below gives:

ResultValue
Pore volume per mass0.75000 L/kg
Surface-to-pore-volume ratio 4/d2.0000e+09 1/m
Internal surface area1,500.0 m²/g

Open this example in the calculator and change any input.

Formula

\(V_{ad} = \frac{\varepsilon_p}{\rho_p}, \quad \frac{A_{ad}}{V_{ad}} = \frac{2\pi RH}{\pi R^2H} = \frac{4}{d_{pore}}, \quad A_{ad} = \frac{4V_{ad}}{d_{pore}}\)

Variables

Symbol Meaning SI unit
\(\varepsilon_p\) Particle porosity (pore volume share) -
\(\rho_p\) Particle (apparent) density kg/m³
\(d_{pore}\) Pore diameter m
\(V_{ad}\) Pore volume per mass m³/kg
\(A_{ad}/V_{ad}\) Surface-to-pore-volume ratio 4/d 1/m
\(A_{ad}\) Internal surface area m²/kg

Method and standards

Geometric surface area of uniform cylindrical pores.

Where it is used

  • Understanding adsorbent specifications.
  • Teaching adsorption fundamentals.

Common mistakes

  • Using bulk density instead of particle density.
  • Mixing nm and m in the pore diameter.

Assumptions and limits

  • Uniform cylindrical pores; external area neglected.

References

  • Cylindrical pore geometry A/V = 4/d with pore volume ε/ρ

Questions and answers

Why does pore size matter so much?

Area per pore volume goes as 4/d: halving the pore diameter doubles the internal area of the same pore volume.

How does this compare with measured BET areas?

Activated carbons measure about 500–1500 m²/g by nitrogen adsorption, consistent with pores of about 1–3 nm.

What do the defaults represent?

An illustrative activated carbon: porosity 0.6, particle density 800 kg/m³ and 2 nm pores.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 15-3, Example 15-1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.