Worked example
Example: Illustrative activated carbon: porosity 0.6, 800 kg/m3, 2 nm pores. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Particle porosity (pore volume share) | 60.000 % |
| Particle (apparent) density | 800.00 kg/m³ |
| Pore diameter | 2.0000 nm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pore volume per mass | 0.75000 L/kg |
| Surface-to-pore-volume ratio 4/d | 2.0000e+09 1/m |
| Internal surface area | 1,500.0 m²/g |
Open this example in the calculator and change any input.
Formula
\(V_{ad} = \frac{\varepsilon_p}{\rho_p}, \quad \frac{A_{ad}}{V_{ad}} = \frac{2\pi RH}{\pi R^2H} = \frac{4}{d_{pore}}, \quad A_{ad} = \frac{4V_{ad}}{d_{pore}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\varepsilon_p\) | Particle porosity (pore volume share) | - |
| \(\rho_p\) | Particle (apparent) density | kg/m³ |
| \(d_{pore}\) | Pore diameter | m |
| \(V_{ad}\) | Pore volume per mass | m³/kg |
| \(A_{ad}/V_{ad}\) | Surface-to-pore-volume ratio 4/d | 1/m |
| \(A_{ad}\) | Internal surface area | m²/kg |
Method and standards
Geometric surface area of uniform cylindrical pores.
Where it is used
- Understanding adsorbent specifications.
- Teaching adsorption fundamentals.
Common mistakes
- Using bulk density instead of particle density.
- Mixing nm and m in the pore diameter.
Assumptions and limits
- Uniform cylindrical pores; external area neglected.
References
- Cylindrical pore geometry A/V = 4/d with pore volume ε/ρ
Questions and answers
Why does pore size matter so much?
Area per pore volume goes as 4/d: halving the pore diameter doubles the internal area of the same pore volume.
How does this compare with measured BET areas?
Activated carbons measure about 500–1500 m²/g by nitrogen adsorption, consistent with pores of about 1–3 nm.
What do the defaults represent?
An illustrative activated carbon: porosity 0.6, particle density 800 kg/m³ and 2 nm pores.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 15-3, Example 15-1