Worked example
Example: Illustrative GAC bed: 1.2 mm, porosity 0.42, sphericity 0.75, 10 m/h, 15 C, D 7e-10. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Particle diameter | 1.2000 mm |
| Bed porosity | 42.000 % |
| Particle sphericity | 75.000 % |
| Superficial velocity | 10.000 m/h |
| Water density | 999.10 kg/m³ |
| Water viscosity | 1.1380 mPa·s |
| Solute diffusivity | 7.0000e-10 m²/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reynolds number ρφd_pv/(εμ) | 5.2259 |
| Schmidt number | 1,627.2 |
| Sherwood number (single particle) | 19.316 |
| Film mass transfer coefficient | 2.1070e-05 m/s |
| Specific particle area 6(1 − ε)/(φd_p) | 3,866.7 m²/m³ |
| Volumetric coefficient | 0.081472 1/s |
Open this example in the calculator and change any input.
Formula
\(k_f = \left[1 + 1.5(1 - \varepsilon)\right]\frac{D_l}{d_p}\left(2 + 0.644\,Re^{1/2}Sc^{1/3}\right)\)
\(Re = \frac{\rho\phi d_pv}{\varepsilon\mu}, \quad Sc = \frac{\mu}{\rho D_l}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d_p\) | Particle diameter | m |
| \(\varepsilon\) | Bed porosity | - |
| \(\phi\) | Particle sphericity | - |
| \(v\) | Superficial velocity | m/s |
| \(\rho\) | Water density | kg/m³ |
| \(\mu\) | Water viscosity | Pa·s |
| \(D_l\) | Solute diffusivity | m²/s |
| \(Re\) | Reynolds number ρφd_pv/(εμ) | - |
| \(Sc\) | Schmidt number | - |
| \(Sh\) | Sherwood number (single particle) | - |
| \(k_f\) | Film mass transfer coefficient | m/s |
| \(a\) | Specific particle area 6(1 − ε)/(φd_p) | m²/m³ |
| \(k_fa\) | Volumetric coefficient | 1/s |
Method and standards
Correlation for external (film) mass transfer to particles in fixed beds.
Where it is used
- GAC and ion exchange column design.
- Limestone (calcite) contactors for corrosion control.
Common mistakes
- Using the superficial velocity without the porosity in Re.
- Taking the gas-phase diffusivity.
Assumptions and limits
- Fixed beds of roughly spherical particles; liquid phase.
References
- Gnielinski's packed-bed correlation for the liquid film coefficient
Questions and answers
Where does the diffusivity come from?
Hayduk–Laudie for neutral organics or Nernst–Haskell for salts; typical values are 0.5–2 × 10⁻⁹ m²/s.
Why does velocity matter so little?
k_f rises only with Re^½; doubling the flow raises the film coefficient by about 40 %.
What do the defaults represent?
An illustrative GAC bed: 1.2 mm granules (porosity 0.42, sphericity 0.75) at 10 m/h and 15 °C for a solute with D 7 × 10⁻¹⁰ m²/s.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 7-5, Table 7-5 and Example 7-5