FireCADCalc

Film Mass Transfer Coefficient in a Packed Bed (Gnielinski)

Liquid film mass transfer coefficient to particles in a packed bed (GAC, ion exchange, limestone contactors) by Gnielinski's correlation.

Inputs

Examples: Illustrative GAC bed: 1.2 mm, porosity 0.42, sphericity 0.75, 10 m/h, 15 C, D 7e-10Ion exchange resin 0.6 mm, 30 m/h, nitrate D 1.9e-9

Accepted: 0.01 to 100 mm
Accepted: 20 to 80 %
Accepted: 30 to 100 %
Accepted: 0.036 to 180 m/h
Accepted: 950 to 1,050 kg/m³
Accepted: 0.2 to 2 mPa·s
Accepted: 1E-11 to 1E-8 m²/s

Results

Gnielinski: k_f = [1 + 1.5(1 − ε)](D_l/d_p)(2 + 0.644 Re^½ Sc^⅓), valid for Re·Sc above about 500 and porosities up to about 0.9.

Reynolds number ρφd_pv/(εμ)13.108
Schmidt number528.32
Sherwood number (single particle)20.849
Film mass transfer coefficient1.2742e-04m/s
Specific particle area 6(1 − ε)/(φd_p)6,200.0m²/m³
Volumetric coefficient0.790011/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative GAC bed: 1.2 mm, porosity 0.42, sphericity 0.75, 10 m/h, 15 C, D 7e-10. The inputs, in the units selected above:

InputValue
Particle diameter1.2000 mm
Bed porosity42.000 %
Particle sphericity75.000 %
Superficial velocity10.000 m/h
Water density999.10 kg/m³
Water viscosity1.1380 mPa·s
Solute diffusivity7.0000e-10 m²/s

Applying the formula below gives:

ResultValue
Reynolds number ρφd_pv/(εμ)5.2259
Schmidt number1,627.2
Sherwood number (single particle)19.316
Film mass transfer coefficient2.1070e-05 m/s
Specific particle area 6(1 − ε)/(φd_p)3,866.7 m²/m³
Volumetric coefficient0.081472 1/s

Open this example in the calculator and change any input.

Formula

\(k_f = \left[1 + 1.5(1 - \varepsilon)\right]\frac{D_l}{d_p}\left(2 + 0.644\,Re^{1/2}Sc^{1/3}\right)\)

\(Re = \frac{\rho\phi d_pv}{\varepsilon\mu}, \quad Sc = \frac{\mu}{\rho D_l}\)

Variables

Symbol Meaning SI unit
\(d_p\) Particle diameter m
\(\varepsilon\) Bed porosity -
\(\phi\) Particle sphericity -
\(v\) Superficial velocity m/s
\(\rho\) Water density kg/m³
\(\mu\) Water viscosity Pa·s
\(D_l\) Solute diffusivity m²/s
\(Re\) Reynolds number ρφd_pv/(εμ) -
\(Sc\) Schmidt number -
\(Sh\) Sherwood number (single particle) -
\(k_f\) Film mass transfer coefficient m/s
\(a\) Specific particle area 6(1 − ε)/(φd_p) m²/m³
\(k_fa\) Volumetric coefficient 1/s

Method and standards

Correlation for external (film) mass transfer to particles in fixed beds.

Where it is used

  • GAC and ion exchange column design.
  • Limestone (calcite) contactors for corrosion control.

Common mistakes

  • Using the superficial velocity without the porosity in Re.
  • Taking the gas-phase diffusivity.

Assumptions and limits

  • Fixed beds of roughly spherical particles; liquid phase.

References

  • Gnielinski's packed-bed correlation for the liquid film coefficient

Questions and answers

Where does the diffusivity come from?

Hayduk–Laudie for neutral organics or Nernst–Haskell for salts; typical values are 0.5–2 × 10⁻⁹ m²/s.

Why does velocity matter so little?

k_f rises only with Re^½; doubling the flow raises the film coefficient by about 40 %.

What do the defaults represent?

An illustrative GAC bed: 1.2 mm granules (porosity 0.42, sphericity 0.75) at 10 m/h and 15 °C for a solute with D 7 × 10⁻¹⁰ m²/s.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 7-5, Table 7-5 and Example 7-5

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.