Diffusivity in Water: Hayduk–Laudie and Nernst–Haskell

Diffusion coefficient of a small neutral molecule in water by Hayduk–Laudie and of a dissolved electrolyte at infinite dilution by Nernst–Haskell.

Inputs

Examples: Benzene (96 cm3/mol) at 20 C; NaClTrichloroethene (Le Bas 107.1 cm3/mol) at 10 C; CaSO4

Accepted: 0.2 to 2 mPa·s
Accepted: 5 to 1,000 cm³/mol
Accepted: 0 to 100 °C
Accepted: 1 to 4
Accepted: 1 to 4
Accepted: 1 to 400
Accepted: 1 to 400

Results

Hayduk–Laudie: D = 13.26 × 10⁻⁹/(μ^1.14 V_b^0.589) m²/s with μ in cP and V_b in cm³/mol (Le Bas increments: C 14.8, H 3.7, Cl 21.6, six-membered ring −15), usually within 10 %. Nernst–Haskell applies at infinite dilution; the temperature enters through RT and the conductances, which are tabulated at 25 °C.

Hayduk–Laudie diffusivity (neutral solute)9.0154e-06cm²/s
Nernst–Haskell diffusivity (electrolyte)1.5844e-05cm²/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Benzene (96 cm3/mol) at 20 C; NaCl. The inputs, in the units selected above:

InputValue
Water viscosity1.0000 mPa·s
Molar volume at the normal boiling point96.000 cm³/mol
Temperature20.000 °C
Cation charge1.0000 -
Anion charge1.0000 -
Cation limiting ionic conductance, cm²·S/eq50.100 -
Anion limiting ionic conductance, cm²·S/eq76.400 -

Applying the formula below gives:

ResultValue
Hayduk–Laudie diffusivity (neutral solute)9.0154e-06 cm²/s
Nernst–Haskell diffusivity (electrolyte)1.5844e-05 cm²/s

Open this example in the calculator and change any input.

Formula

\(D_{HL} = \frac{13.26\times10^{-9}}{\mu_w^{1.14}V_b^{0.589}}\;\mathrm{m^2/s} \quad (\mu_w\ \mathrm{in\ cP},\ V_b\ \mathrm{in\ cm^3/mol})\)

\(D_{NH} = \frac{RT}{F^2}\,\frac{1/|z_+| + 1/|z_-|}{1/\lambda_+ + 1/\lambda_-}\)

Variables

Symbol Meaning SI unit
\(\mu_w\) Water viscosity Pa·s
\(V_b\) Molar volume at the normal boiling point m³/mol
\(T\) Temperature K
\(|z_+|\) Cation charge -
\(|z_-|\) Anion charge -
\(\lambda_+\) Cation limiting ionic conductance, cm²·S/eq -
\(\lambda_-\) Anion limiting ionic conductance, cm²·S/eq -
\(D_{HL}\) Hayduk–Laudie diffusivity (neutral solute) m²/s
\(D_{NH}\) Nernst–Haskell diffusivity (electrolyte) m²/s

Method and standards

Empirical diffusivity of neutral solutes in water and the Nernst–Haskell limit for electrolytes.

Where it is used

  • Mass transfer coefficients for stripping, adsorption and membranes.
  • Ion transport estimates.

Common mistakes

  • Using the molar volume at 25 °C instead of at the boiling point.
  • Applying Nernst–Haskell to concentrated solutions.

Assumptions and limits

  • Dilute aqueous solutions.

Questions and answers

How do I get the molar volume?

Add Le Bas atomic increments: vinyl chloride C₂H₃Cl = 2 × 14.8 + 3 × 3.7 + 21.6 = 62.3 cm³/mol; benzene 6 × 14.8 + 6 × 3.7 − 15 = 96 cm³/mol.

Hayduk–Laudie or Wilke–Chang?

Hayduk–Laudie is written for water as the solvent and needs no association factor; Wilke–Chang covers other solvents.

What do the defaults represent?

An illustrative case: Benzene (96 cm3/mol) at 20 C; NaCl. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 7-3, eqs. 7-32 and 7-35, Tables 7-3 and 7-4 and Examples 7-1 and 7-2 (Hayduk and Laudie 1974; Nernst 1888, Haskell 1908)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.