Worked example
Example: Water vapour in air, 25 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Temperature | 25.000 °C |
| Pressure (absolute) | 101.33 kPa |
| Molar mass of A | 18.015 kg/kmol |
| Molar mass of B | 28.960 kg/kmol |
| Diffusion volume of A | 13.100 - |
| Diffusion volume of B | 19.700 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Diffusion coefficient | 0.25090 cm²/s |
Open this example in the calculator and change any input.
Formula
\(D_{AB} = \frac{10^{-3}\,T^{1.75}\sqrt{1/M_A + 1/M_B}}{p\left[(\Sigma v_A)^{1/3} + (\Sigma v_B)^{1/3}\right]^2}\ \ (\mathrm{cm^2/s};\ T\ \mathrm{K},\ p\ \mathrm{atm})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T\) | Temperature | K |
| \(p\) | Pressure | Pa |
| \(M_A\) | Molar mass of A | kg/kmol |
| \(M_B\) | Molar mass of B | kg/kmol |
| \(\Sigma v_A\) | Diffusion volume of A | - |
| \(\Sigma v_B\) | Diffusion volume of B | - |
| \(D_{AB}\) | Diffusion coefficient | m²/s |
Method and standards
Fuller–Schettler–Giddings correlation.
Where it is used
- Mass transfer, drying and evaporation calculations.
Common mistakes
- Using at high pressure.
- Mixing diffusion volumes from other methods.
Assumptions and limits
- Low pressure (absolute); nonpolar or weakly polar gases. A note appears above about 10 bar.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 5
- Eq. (5-202) and Table 5-12 (Fuller, Schettler and Giddings)
Questions and answers
What are diffusion volumes?
Fuller's additive atomic and molecular volumes; for example water 13.1, air 19.7, CO₂ 26.9.
How does it change with temperature and pressure?
Roughly as T^1.75 and 1/p.
What do the defaults give?
Water vapour in air at 25 °C: about 0.25 cm²/s (measured 0.26).
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.