FireCADCalc

Heat of Vaporisation by Corresponding States (Pitzer)

Heat of vaporisation of a pure liquid at a temperature from its critical temperature and acentric factor by corresponding states (Perry's Eq. 2-41).

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Anisole 452 K (Perry's example: 36.70 kJ/mol)Benzene at 353.2 K (normal boiling point)

Results

Perry's: uncertainty under about 6 % for organic compounds. Estimate for design; use measured data where they exist.

Molar heat of vaporisation36.697kJ/mol
Specific heat of vaporisation339.35kJ/kg
Reduced temperature0.70012

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Anisole 452 K (Perry's example: 36.70 kJ/mol). The inputs, in the units selected above:

InputValue
Temperature178.85 °C
Critical temperature372.45 °C
Acentric factor0.35017 -
Molar mass108.14 kg/kmol

Applying the formula below gives:

ResultValue
Molar heat of vaporisation36.697 kJ/mol
Specific heat of vaporisation339.35 kJ/kg
Reduced temperature0.70012

Open this example in the calculator and change any input.

Formula

\(\frac{\Delta H_v}{RT_c} = 7.08\tau^{0.354} + 10.95\,\omega\,\tau^{0.456}, \quad \tau = 1 - T_r\)

Variables

Symbol Meaning SI unit
\(T\) Temperature K
\(T_c\) Critical temperature K
\(\omega\) Acentric factor -
\(M\) Molar mass kg/kmol
\(\Delta H_v\) Molar heat of vaporisation J/mol
\(\Delta h_v\) Specific heat of vaporisation J/kg
\(T_r\) Reduced temperature -

Method and standards

Corresponding-states correlation.

Where it is used

  • Reboiler and condenser duties for organics.
  • Evaporator design for solvents.

Common mistakes

  • Using above T_c.
  • Using per-mole results as per-kg.

Assumptions and limits

  • Organic compounds; 0.6 < T_r < 1.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 2
  • Eq. (2-41) (corresponding states, from Poling, Prausnitz and O'Connell) with the anisole example

Questions and answers

What does Perry's example give?

Anisole at 452 K: 36.70 kJ/mol, 2.2 % below the DIPPR value of 37.51.

How is this different from Watson?

Watson scales a known heat of vaporisation to another temperature; this estimates it from critical data alone.

Does it work for water?

Roughly; use the steam tables for water.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.