Acentric Factor from a Vapour Pressure

Pitzer's acentric factor from the vapour pressure at a reduced temperature of 0.7, interpolated from two measured vapour-pressure points.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Ammonia (page defaults, FAQ)Propylene-like (bracketing 0.7 Tc)Water: 473.15 K and 483.15 K (IF97 pressures)

Results

Temperature at T_r = 0.710.805°C
Vapour pressure at T_r = 0.76.2905bar
Acentric factor0.25362

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ammonia (page defaults, FAQ). The inputs, in the units selected above:

InputValue
Critical temperature132.50 °C
Critical pressure112.80 bar
Temperature of vapour-pressure point 1-13.150 °C
Vapour pressure at T₁2.5520 bar
Temperature of vapour-pressure point 226.850 °C
Vapour pressure at T₂10.620 bar

Applying the formula below gives:

ResultValue
Temperature at T_r = 0.710.805 °C
Vapour pressure at T_r = 0.76.2905 bar
Acentric factor0.25362

Open this example in the calculator and change any input.

Formula

\(\omega = -\log_{10}\left(\frac{p_s}{p_c}\right)_{T_r = 0.7} - 1, \quad \ln\frac{p_s}{p_1} = \beta\left(\frac{1}{T_1} - \frac{1}{T}\right)\)

Variables

Symbol Meaning SI unit
\(T_c\) Critical temperature K
\(p_c\) Critical pressure Pa
\(T_1\) Temperature of vapour-pressure point 1 K
\(p_1\) Vapour pressure at T₁ Pa
\(T_2\) Temperature of vapour-pressure point 2 K
\(p_2\) Vapour pressure at T₂ Pa
\(0.7T_c\) Temperature at T_r = 0.7 K
\(p_s(0.7T_c)\) Vapour pressure at T_r = 0.7 Pa
\(\omega\) Acentric factor -

Method and standards

Definition with two-point interpolation.

Where it is used

  • Getting ω for equations of state when it is not tabulated.

Common mistakes

  • Extrapolating far from the data.
  • Using gauge pressures.

Assumptions and limits

  • Clausius–Clapeyron between the points.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 2 (acentric factor definition ω = −log₁₀(p_s/p_c)|T_r=0.7 − 1)
  • ln p linear in 1/T between the two points (Clausius–Clapeyron)

Questions and answers

What does ω measure?

How far a molecule's vapour pressure curve departs from that of a simple spherical molecule (argon, ω ≈ 0).

Why T_r = 0.7?

Pitzer chose it because simple fluids have p_s/p_c = 0.1 there.

What do the defaults represent?

Ammonia (260 K at 2.55 bar, 300 K at 10.6 bar): ω about 0.25, against 0.253 tabulated.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.