Worked example
Example: Ammonia (page defaults, FAQ). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Critical temperature | 132.50 °C |
| Critical pressure | 112.80 bar |
| Temperature of vapour-pressure point 1 | -13.150 °C |
| Vapour pressure at T₁ | 2.5520 bar |
| Temperature of vapour-pressure point 2 | 26.850 °C |
| Vapour pressure at T₂ | 10.620 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Temperature at T_r = 0.7 | 10.805 °C |
| Vapour pressure at T_r = 0.7 | 6.2905 bar |
| Acentric factor | 0.25362 |
Open this example in the calculator and change any input.
Formula
\(\omega = -\log_{10}\left(\frac{p_s}{p_c}\right)_{T_r = 0.7} - 1, \quad \ln\frac{p_s}{p_1} = \beta\left(\frac{1}{T_1} - \frac{1}{T}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_c\) | Critical temperature | K |
| \(p_c\) | Critical pressure | Pa |
| \(T_1\) | Temperature of vapour-pressure point 1 | K |
| \(p_1\) | Vapour pressure at T₁ | Pa |
| \(T_2\) | Temperature of vapour-pressure point 2 | K |
| \(p_2\) | Vapour pressure at T₂ | Pa |
| \(0.7T_c\) | Temperature at T_r = 0.7 | K |
| \(p_s(0.7T_c)\) | Vapour pressure at T_r = 0.7 | Pa |
| \(\omega\) | Acentric factor | - |
Method and standards
Definition with two-point interpolation.
Where it is used
- Getting ω for equations of state when it is not tabulated.
Common mistakes
- Extrapolating far from the data.
- Using gauge pressures.
Assumptions and limits
- Clausius–Clapeyron between the points.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 2 (acentric factor definition ω = −log₁₀(p_s/p_c)|T_r=0.7 − 1)
- ln p linear in 1/T between the two points (Clausius–Clapeyron)
Questions and answers
What does ω measure?
How far a molecule's vapour pressure curve departs from that of a simple spherical molecule (argon, ω ≈ 0).
Why T_r = 0.7?
Pitzer chose it because simple fluids have p_s/p_c = 0.1 there.
What do the defaults represent?
Ammonia (260 K at 2.55 bar, 300 K at 10.6 bar): ω about 0.25, against 0.253 tabulated.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.