Worked example
Example: Propane 400 K, 20 bar. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Temperature | 126.85 °C |
| Pressure (absolute) | 20.000 bar |
| Critical temperature | 96.650 °C |
| Critical pressure | 42.480 bar |
| Acentric factor | 0.15200 - |
| Molar mass | 44.097 kg/kmol |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reduced temperature | 1.0817 |
| Reduced pressure | 0.47081 |
| B⁰ = 0.083 − 0.422/T_r^1.6 | -0.28919 |
| B¹ = 0.139 − 0.172/T_r^4.2 | 0.015309 |
| Compressibility factor | 0.87514 |
| Density | 30.302 kg/m³ |
Open this example in the calculator and change any input.
Formula
\(Z = 1 + \left(B^0 + \omega B^1\right)\frac{p_r}{T_r}, \quad B^0 = 0.083 - \frac{0.422}{T_r^{1.6}}, \quad B^1 = 0.139 - \frac{0.172}{T_r^{4.2}}\)
Variables
| Symbol | Meaning | SI unit | |
|---|---|---|---|
| \(T\) | Temperature | K | |
| \(p\) | Pressure (absolute) | Pa | |
| \(T_c\) | Critical temperature | K | |
| \(p_c\) | Critical pressure | Pa | |
| \(\omega\) | Acentric factor | - | |
| \(M\) | Molar mass | kg/kmol | |
| \(T_r\) | Reduced temperature | - | |
| \(p_r\) | Reduced pressure | - | |
| \(B^0\) | B⁰ = 0.083 − 0.422/T_r1.6 | - | |
| \(B^1\) | B¹ = 0.139 − 0.172/T_r4.2 | - | |
| \(Z\) | Compressibility factor | - | |
| \(\rho\) | Density | kg/m³ |
Method and standards
Pitzer–Abbott.
Where it is used
- Gas metering and compressor calculations.
- Fuel gas density at line pressure.
Common mistakes
- Using it for liquids.
- Gauge pressure.
Assumptions and limits
- Non-polar or slightly polar gases.
- Gas phase only. No phase check is made: below the critical temperature make sure the pressure is below the vapour pressure, or the result is meaningless.
References
- Pitzer generalised second-virial correlation with the Abbott equations (Smith, Van Ness and Abbott, Introduction to Chemical Engineering Thermodynamics)
Questions and answers
Propane at 400 K and 20 bar?
Z about 0.875.
When is it valid?
Gases at low to moderate reduced pressure; near saturation or high pressure use a cubic equation.
Polar gases?
Errors grow for strongly polar or hydrogen-bonding gases.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.