Worked example
Example: CO2 at 300 K, 0.5 L/mol. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Temperature | 26.850 °C |
| Molar volume | 0.50000 L/mol |
| Critical temperature | 30.980 °C |
| Critical pressure | 73.770 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| a = 27R²T_c²/(64p_c) (Pa·m⁶/mol²) | 0.36567 |
| b = RT_c/(8p_c) | 0.042847 L/mol |
| Pressure | 39.936 bar |
| Ideal gas pressure | 49.887 bar |
| Compressibility pv/RT | 0.80053 |
Open this example in the calculator and change any input.
Formula
\(p = \frac{RT}{v - b} - \frac{a}{v^2}, \quad a = \frac{27R^2T_c^2}{64p_c}, \quad b = \frac{RT_c}{8p_c}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T\) | Temperature | K |
| \(v\) | Molar volume | m³/mol |
| \(T_c\) | Critical temperature | K |
| \(p_c\) | Critical pressure | Pa |
| \(a\) | a = 27R²T_c²/(64p_c) (Pa·m⁶/mol²) | - |
| \(b\) | b = RT_c/(8p_c) | m³/mol |
| \(p\) | Pressure | Pa |
| \(p_{ideal}\) | Ideal gas pressure | Pa |
| \(Z\) | Compressibility pv/RT | - |
Method and standards
Van der Waals.
Where it is used
- Teaching and examinations.
- Quick real-gas checks.
Common mistakes
- Specific instead of molar volume.
- Using it for design.
Assumptions and limits
- Pure gas.
References
- Van der Waals (1873) equation with a and b from the critical point
Questions and answers
CO₂ at 300 K and 0.5 L/mol?
About 40 bar by van der Waals against 50 bar ideal.
Why are a and b from the critical point?
Matching the critical inflection fixes both constants.
How accurate?
Rough; it shows the trends but not design accuracy.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.