FireCADCalc

Liquid Thermal Conductivity (Pachaiyappan, Missenard)

Thermal conductivity of an organic liquid: modified Pachaiyappan for hydrocarbons, and Missenard from boiling point, density and heat capacity.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: n-Butylbenzene 333.15 K (Perry's: 0.112 W/(m K) Pachaiyappan)m-Xylene 350 K (Perry's: 123.3 mW/(m K) Missenard)

Results

Pachaiyappan applies to hydrocarbons only (about 10 %); Missenard to nonassociating organics (about 20 %). Estimate for design; use measured data where they exist.

Thermal conductivity, Pachaiyappan0.11207W/(m·K)
Missenard conductivity at 0 °C0.12558W/(m·K)
Thermal conductivity, Missenard0.11457W/(m·K)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: n-Butylbenzene 333.15 K (Perry's: 0.112 W/(m K) Pachaiyappan). The inputs, in the units selected above:

InputValue
Temperature60.000 °C
Critical temperature387.35 °C
Molar mass134.22 kg/kmol
Hydrocarbon class (Pachaiyappan)Branched, cyclic or aromatic
Molar volume at 20 °C162.01 cm³/mol
Normal boiling point (Missenard)183.25 °C
Liquid molar density at 0 °C (kmol/m³)6.5300 -
Liquid heat capacity at 0 °C (J/(mol·K))225.00 -
Atoms in the molecule24.000 -

Applying the formula below gives:

ResultValue
Thermal conductivity, Pachaiyappan0.11207 W/(m·K)
Missenard conductivity at 0 °C0.12724 W/(m·K)
Thermal conductivity, Missenard0.11609 W/(m·K)

Open this example in the calculator and change any input.

Formula

\(k = \frac{CM^m}{V_{293}}\cdot\frac{3 + 20(1 - T_r)^{2/3}}{3 + 20(1 - T_{r,293})^{2/3}}\ \ (C = 0.1811,\ m = 1.001\ \text{or}\ C = 0.4407,\ m = 0.7717)\)

\(k_{273} = \frac{8.4\,T_b^{1/2}\rho_{273}^{1/2}M^{-1/2}C_{p,273}}{n_A^{1/4}}\ \mathrm{mW/(m\,K)}\ (\rho\ \mathrm{mol/cm^3})\)

Variables

Symbol Meaning SI unit
\(T\) Temperature K
\(T_c\) Critical temperature K
\(M\) Molar mass kg/kmol
\(\text{class}\) Hydrocarbon class (Pachaiyappan) -
\(V_{293}\) Molar volume at 20 °C m³/mol
\(T_b\) Normal boiling point (Missenard) K
\(\rho_{273}\) Liquid molar density at 0 °C (kmol/m³) -
\(C_{p,273}\) Liquid heat capacity at 0 °C (J/(mol·K)) -
\(n_A\) Atoms in the molecule -
\(k_{P}\) Thermal conductivity, Pachaiyappan W/(m·K)
\(k_{273}\) Missenard conductivity at 0 °C W/(m·K)
\(k_{M}\) Thermal conductivity, Missenard W/(m·K)

Method and standards

Modified Pachaiyappan; Missenard with Perry's temperature correction.

Where it is used

  • Heat exchanger design for hydrocarbons and solvents.

Common mistakes

  • Using Pachaiyappan for non-hydrocarbons.
  • Wrong density units (Missenard uses mol/cm³).

Assumptions and limits

  • Low to moderate pressure; the liquid state is not checked, but a note appears above the normal boiling point.
  • The Missenard defaults (molar density 6.36 kmol/m³, C_p 225 J/(mol·K), 24 atoms) are illustrative n-butylbenzene-like values without a particular source; the second preset uses Perry's m-xylene data. The 273 K reference in the Missenard temperature correction follows the 0 °C basis of k₂₇₃; using 273.15 K would change the result by far less than its accuracy.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 2
  • Eqs. (2-109)
  • (2-111) and (2-112) (modified Pachaiyappan; Missenard) with the n-butylbenzene and m-xylene examples

Questions and answers

What do Perry's examples give?

n-Butylbenzene at 333.15 K: 0.112 W/(m·K) by Pachaiyappan (0.118 measured); m-xylene at 350 K: 0.123 by Missenard (0.118 in DIPPR).

Why does conductivity fall with temperature?

The liquid expands and its molecules move apart; the 3 + 20(1 − T_r)^⅔ factor captures that.

What do the Missenard defaults represent?

Illustrative n-butylbenzene data for comparison with Pachaiyappan; enter your own.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.