Worked example
Example: Benzene 20 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Parachor (cm³·g^¼/(s^½·mol)) | 206.00 - |
| Liquid density | 879.00 kg/m³ |
| Vapour density | 0.30000 kg/m³ |
| Molar mass | 78.110 kg/kmol |
Applying the formula below gives:
| Result | Value |
|---|---|
| Surface tension | 28.841 mN/m |
Open this example in the calculator and change any input.
Formula
\(\sigma^{1/4} = [P](\rho_L - \rho_V)\ \ (\sigma\ \mathrm{dyn/cm};\ \rho\ \mathrm{mol/cm^3})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \([P]\) | Parachor (cm³·g¼/(s½·mol)) | - |
| \(\rho_L\) | Liquid density | kg/m³ |
| \(\rho_V\) | Vapour density | kg/m³ |
| \(M\) | Molar mass | kg/kmol |
| \(\sigma\) | Surface tension | N/m |
Method and standards
Macleod–Sugden relation.
Where it is used
- Estimating σ at another temperature from density.
Common mistakes
- Using mass density without dividing by M.
Assumptions and limits
- Pure, nonassociated liquids.
- The fourth power makes the result sensitive to density: the default 876 kg/m³ and the preset's 879 kg/m³ differ by 0.3 % but give 28.5 and 28.8 mN/m.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 2 (surface tension: parachor method of Macleod and Sugden)
Questions and answers
Why the fourth power?
Small errors in parachor or density are multiplied fourfold: 1 % in density gives 4 % in σ.
Where do parachors come from?
Additive group values or a measured surface tension at one temperature.
What do the defaults represent?
Benzene at 20 °C: about 28.5 mN/m with the default density of 876 kg/m³ (28.8 with 879 kg/m³, as in the preset); measured about 28.9 mN/m.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.