Worked example
Example: CO2 350 K, 20 MPa (Perry's example: 0.0489 mPa s). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Temperature | 76.850 °C |
| Pressure | 200.00 bar |
| Compressibility factor at T and p | 0.49830 - |
| Critical temperature | 31.060 °C |
| Critical pressure | 73.830 bar |
| Critical compressibility factor | 0.27400 - |
| Molar mass | 44.010 kg/kmol |
| Low-pressure viscosity at T | 0.017400 cP |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reduced density | 1.2947 |
| Viscosity-reducing parameter (1/(mPa·s)) | 224.08 |
| Viscosity at T and p | 0.048854 cP |
| Pressure correction factor | 2.8077 |
Open this example in the calculator and change any input.
Formula
\(\left[(\eta - \eta^\circ)\xi + 1\right]^{1/4} = 1.0230 + 0.23364\rho_r + 0.58533\rho_r^2 - 0.40758\rho_r^3 + 0.093324\rho_r^4\)
\(\xi = 2173.4\,T_c^{1/6}M^{-1/2}p_c^{-2/3}\ \ (T_c\ \mathrm{K},\ p_c\ \mathrm{MPa}), \quad \rho_r = \frac{pZ_cT_c}{ZTp_c}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T\) | Temperature | K |
| \(p\) | Pressure | Pa |
| \(Z\) | Compressibility factor at T and p | - |
| \(T_c\) | Critical temperature | K |
| \(p_c\) | Critical pressure | Pa |
| \(Z_c\) | Critical compressibility factor | - |
| \(M\) | Molar mass | kg/kmol |
| \(\eta^\circ\) | Low-pressure viscosity at T | Pa·s |
| \(\rho_r\) | Reduced density | - |
| \(\xi\) | Viscosity-reducing parameter (1/(mPa·s)) | - |
| \(\eta\) | Viscosity at T and p | Pa·s |
| \(\eta/\eta^\circ\) | Pressure correction factor | - |
Method and standards
Residual viscosity correlation.
Where it is used
- Supercritical CO₂, high-pressure gas lines and compressors.
Common mistakes
- Using it for polar gases.
- Using a Z for another condition.
Assumptions and limits
- Nonpolar gases; 0.1 < ρ_r < 3.
- Z and the low-pressure viscosity are inputs and are not checked against T and p: Z must come from an equation of state at the same T and p (Z = 1 at high pressure gives a wrong reduced density), and the low-pressure viscosity must be at the same T.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 2
- Eqs. (2-88) and (2-93) (Jossi, Stiel and Thodos) with the CO₂ example
Questions and answers
What does Perry's example give?
CO₂ at 350 K and 20 MPa: 0.0489 mPa·s against 0.0473 measured (3.4 %).
Where do I get Z?
From an equation of state (Peng–Robinson or Lee–Kesler) at the same T and p.
Why is viscosity a function of density?
At high pressure, molecules are close and collisions transfer momentum more effectively; the excess over the dilute-gas value depends mainly on density.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.