Worked example
Example: NH3 absorption, 50 mm metal Pall rings (102 m2/m3), steel. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Liquid mass flux | 8.0000 kg/(m²·s) |
| Gas mass flux | 1.5000 kg/(m²·s) |
| Packing specific area | 0.10200 m²/L |
| Nominal packing size | 50.000 mm |
| Critical surface tension of the packing (ceramic 61, steel 75, polyethylene 33) | 75.000 mN/m |
| Liquid surface tension | 72.000 mN/m |
| Liquid viscosity | 1.0000 mPa·s |
| Liquid density | 998.00 kg/m³ |
| Liquid diffusivity | 2.0000e-09 m²/s |
| Gas viscosity | 0.018000 mPa·s |
| Gas density | 1.2000 kg/m³ |
| Gas diffusivity | 2.1000e-05 m²/s |
| Temperature | 25.000 °C |
| Pressure | 1.0130 bar |
| Liquid molar mass | 18.000 kg/kmol |
| Gas molar mass | 29.000 kg/kmol |
| Equilibrium line slope (y = mx) | 1.2000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Wetted fraction of packing area | 72.514 % |
| Effective interfacial area | 73.964 m²/m³ |
| Liquid film coefficient | 0.21258 mm/s |
| Gas film coefficient, kmol/(m²·s·bar) | 0.001697 |
| Gas film transfer unit height | 0.40671 m |
| Liquid film transfer unit height | 0.50982 m |
| Stripping factor | 0.13966 |
| Overall gas-phase transfer unit height | 0.47791 m |
Open this example in the calculator and change any input.
Formula
\(\frac{a_w}{a} = 1 - \exp\left[-1.45\left(\frac{\sigma_c}{\sigma_L}\right)^{0.75}\left(\frac{L_w^*}{a\mu_L}\right)^{0.1}\left(\frac{L_w^{*2}a}{\rho_L^2g}\right)^{-0.05}\left(\frac{L_w^{*2}}{\rho_L\sigma_La}\right)^{0.2}\right]\)
\(k_L\left(\frac{\rho_L}{\mu_Lg}\right)^{1/3} = 0.0051\left(\frac{L_w^*}{a_w\mu_L}\right)^{2/3}\left(\frac{\mu_L}{\rho_LD_L}\right)^{-1/2}(ad_p)^{0.4}, \quad \frac{k_GRT}{aD_v} = K_5\left(\frac{V_w^*}{a\mu_v}\right)^{0.7}\left(\frac{\mu_v}{\rho_vD_v}\right)^{1/3}(ad_p)^{-2.0}\)
\(H_G = \frac{G_m}{k_Ga_wP}, \quad H_L = \frac{L_m}{k_La_wC_t}, \quad H_{OG} = H_G + m\frac{G_m}{L_m}H_L\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L_w^*\) | Liquid mass flux | kg/(m²·s) |
| \(V_w^*\) | Gas mass flux | kg/(m²·s) |
| \(a\) | Packing specific area | m²/m³ |
| \(d_p\) | Nominal packing size | m |
| \(\sigma_c\) | Critical surface tension of the packing (ceramic 61, steel 75, polyethylene 33) | N/m |
| \(\sigma_L\) | Liquid surface tension | N/m |
| \(\mu_L\) | Liquid viscosity | Pa·s |
| \(\rho_L\) | Liquid density | kg/m³ |
| \(D_L\) | Liquid diffusivity | m²/s |
| \(\mu_v\) | Gas viscosity | Pa·s |
| \(\rho_v\) | Gas density | kg/m³ |
| \(D_v\) | Gas diffusivity | m²/s |
| \(T\) | Temperature | K |
| \(P\) | Pressure | Pa |
| \(M_L\) | Liquid molar mass | kg/kmol |
| \(M_V\) | Gas molar mass | kg/kmol |
| \(m\) | Equilibrium line slope (y = mx) | - |
| \(a_w/a\) | Wetted fraction of packing area | - |
| \(a_w\) | Effective interfacial area | m²/m³ |
| \(k_L\) | Liquid film coefficient | m/s |
| \(k_G\) | Gas film coefficient, kmol/(m²·s·bar) | - |
| \(H_G\) | Gas film transfer unit height | m |
| \(H_L\) | Liquid film transfer unit height | m |
| \(mG_m/L_m\) | Stripping factor | - |
| \(H_{OG}\) | Overall gas-phase transfer unit height | m |
Method and standards
Onda's film coefficient and wetted-area correlations.
Where it is used
- Packed absorber and stripper design.
- Comparing packing materials and sizes.
Common mistakes
- Using the total packing area instead of the wetted area.
- Mixing K₅ values for small and large packings.
Assumptions and limits
- Random packings; Onda's data range.
Questions and answers
Why does the packing material matter?
Through its critical surface tension: water wets ceramics (61 mN/m) and metals better than plastics (33 mN/m), so more of a plastic packing's area stays dry.
How is H_OG used?
Packed height Z = H_OG × N_OG; N_OG comes from the Colburn equation or a numerical integration.
What do the defaults represent?
An illustrative case: NH3 absorption, 50 mm metal Pall rings (102 m2/m3), steel. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Sinnott, Coulson and Richardson's Chemical Engineering Vol. 6: Chemical Engineering Design, 4th ed. (Elsevier, 2005), sec. 11.14.4, eqs. 11.113 to 11.117 and Example 11.14 (Onda, Takeuchi and Okumoto, 1968)