FireCADCalc

Van Winkle Plate Efficiency Correlation (Murphree EMV)

Murphree vapour efficiency of a sieve or bubble-cap tray from surface tension, liquid properties, vapour velocity, weir height and free area by Van Winkle.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Hydrocarbon tray: 15 mN/m, 0.2 mPa s, 600 and 15 kg/m3, 1.0 m/s, 50 mm weir, FA 0.10Vacuum column: 25 mN/m, 0.6 mPa s, 850 and 0.3 kg/m3, 2.5 m/s, 25 mm weir, FA 0.12

Accepted: 1 to 100 mN/m
Accepted: 0.01 to 50 mPa·s
Accepted: 300 to 2,000 kg/m³
Accepted: 0.05 to 200 kg/m³
Accepted: 1E-11 to 1E-7 m²/s
Accepted: 0.01 to 10 m/s
Accepted: 5 to 200 mm
Accepted: 1 to 50 %

Results

Van Winkle et al. (1972) fitted binary-system data for sieve and bubble-cap trays; it gives point-to-tray efficiencies of the right order for preliminary design. Values above 1 can occur with long flow paths.

Surface tension number75.000
Liquid Schmidt number55.556
Reynolds number37,500
Murphree vapour efficiency81.229%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hydrocarbon tray: 15 mN/m, 0.2 mPa s, 600 and 15 kg/m3, 1.0 m/s, 50 mm weir, FA 0.10. The inputs, in the units selected above:

InputValue
Liquid surface tension15.000 mN/m
Liquid viscosity0.20000 mPa·s
Liquid density600.00 kg/m³
Vapour density15.000 kg/m³
Liquid diffusivity of the light key6.0000e-09 m²/s
Superficial vapour velocity1.0000 m/s
Weir height50.000 mm
Fractional free area (hole area / column area)10.000 %

Applying the formula below gives:

ResultValue
Surface tension number75.000
Liquid Schmidt number55.556
Reynolds number37,500
Murphree vapour efficiency81.229 %

Open this example in the calculator and change any input.

Formula

\(E_{mV} = 0.07\,Dg^{0.14}Sc_L^{0.25}Re^{0.08}\)

\(Dg = \frac{\sigma_L}{\mu_Lu_v}, \quad Sc_L = \frac{\mu_L}{\rho_LD_{LK}}, \quad Re = \frac{h_wu_v\rho_v}{\mu_L(FA)}\)

Variables

Symbol Meaning SI unit
\(\sigma_L\) Liquid surface tension N/m
\(\mu_L\) Liquid viscosity Pa·s
\(\rho_L\) Liquid density kg/m³
\(\rho_v\) Vapour density kg/m³
\(D_{LK}\) Liquid diffusivity of the light key m²/s
\(u_v\) Superficial vapour velocity m/s
\(h_w\) Weir height m
\(FA\) Fractional free area (hole area / column area) -
\(Dg\) Surface tension number -
\(Sc_L\) Liquid Schmidt number -
\(Re\) Reynolds number -
\(E_{mV}\) Murphree vapour efficiency -

Method and standards

Van Winkle's dimensionless efficiency correlation.

Where it is used

  • Preliminary tray efficiency for column design.
  • Comparing the effect of weir height and vapour rate.

Common mistakes

  • Using vapour viscosity in the groups.
  • Using the hole velocity as u_v.

Assumptions and limits

  • Binary systems within the correlation's data range.

Questions and answers

How does it differ from O'Connell?

O'Connell gives an overall column efficiency from relative volatility and viscosity only; Van Winkle uses tray geometry and vapour rate as well.

Which diffusivity should I use?

The liquid-phase diffusivity of the light key in the mixture at tray conditions, for example by Wilke–Chang.

What do the defaults represent?

An illustrative case: Hydrocarbon tray: 15 mN/m, 0.2 mPa s, 600 and 15 kg/m3, 1.0 m/s, 50 mm weir, FA 0.10. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Sinnott, Coulson and Richardson's Chemical Engineering Vol. 6: Chemical Engineering Design, 4th ed. (Elsevier, 2005), sec. 11.10.5, eq. 11.69 (Van Winkle, MacFarland and Sigmund, 1972) and Example 11.13

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.