FireCADCalc

Dispersion Number of an Open-Channel or Contact Basin

Velocity, hydraulic radius, Reynolds number, longitudinal dispersion coefficient and dispersion number of flow through an open channel or serpentine contactor.

Inputs

Examples: Baffled contact tank: 20,000 m3/d, 2 m wide, 4 m deep, 300 m pathUnbaffled tank 10,000 m3/d, 15 m wide, 4 m deep, 30 m

Accepted: 0.864 to 8,640,000 m³/d
Accepted: 0.1 to 100 m
Accepted: 0.1 to 50 m
Accepted: 1 to 10,000 m
Accepted: 2E-7 to 2E-6 m²/s

Results

Empirical dispersion coefficient for turbulent open-channel flow. Dispersion numbers below about 0.025 approach plug flow; baffling a contact tank lengthens the path and lowers d.

Mean velocity0.001929m/s
Hydraulic radius2.6087m
Reynolds number (4vR_h/ν)20,069
Longitudinal dispersion coefficient0.005893m²/s
Dispersion number E/(vL)0.10183
Mean hydraulic residence time259.20min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Baffled contact tank: 20,000 m3/d, 2 m wide, 4 m deep, 300 m path. The inputs, in the units selected above:

InputValue
Flow20,000 m³/d
Channel width2.0000 m
Water depth4.0000 m
Channel length (flow path)300.00 m
Kinematic viscosity1.3100e-06 m²/s

Applying the formula below gives:

ResultValue
Mean velocity0.028935 m/s
Hydraulic radius0.80000 m
Reynolds number (4vR_h/ν)70,681
Longitudinal dispersion coefficient0.023160 m²/s
Dispersion number E/(vL)0.002668
Mean hydraulic residence time172.80 min

Open this example in the calculator and change any input.

Formula

\(Re = \frac{4vR_h}{\nu}, \quad E = 1.01\nu Re^{0.875}, \quad d = \frac{E}{vL}\)

Variables

Symbol Meaning SI unit
\(Q\) Flow m³/s
\(W\) Channel width m
\(h\) Water depth m
\(L\) Channel length (flow path) m
\(\nu\) Kinematic viscosity m²/s
\(v\) Mean velocity m/s
\(R_h\) Hydraulic radius m
\(Re\) Reynolds number (4vR_h/ν) -
\(E\) Longitudinal dispersion coefficient m²/s
\(d\) Dispersion number E/(vL) -
\(\tau\) Mean hydraulic residence time s

Method and standards

Empirical longitudinal dispersion in open channels.

Where it is used

  • Contact tank and channel design for CT credit.
  • Interpreting tracer tests.

Common mistakes

  • Using the depth instead of the hydraulic radius.
  • Comparing d from tracer tests with a different definition.

Assumptions and limits

  • Turbulent, uniform channel flow.

Questions and answers

Why does dispersion matter for disinfection?

Credit is given on T10, the time for 10 % of a tracer to pass; low dispersion makes T10 close to the mean time.

How do I reduce d?

Increase the length-to-width ratio of the flow path with baffles; ratios above 40:1 approach plug flow.

What do the defaults represent?

An illustrative case: Baffled contact tank: 20,000 m3/d, 2 m wide, 4 m deep, 300 m path. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 6-7, eq. 6-113 and Example 6-6

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.