FireCADCalc

Henry's Law Constant at Another Temperature (van 't Hoff)

Henry's law constant of a gas or volatile compound corrected from one temperature to another with its enthalpy of dissolution by the van 't Hoff relation.

Inputs

Examples: TCE 0.42 at 20 C to 10 C groundwater, dH 32 kJ/molOxygen solubility-form constant, enter dH negative: 1.3e-3 at 25 C to 10 C

Accepted: 1E-9 to 1E+9
Accepted: 0 to 100 °C
Accepted: -200 to 200 kJ/mol
Accepted: 0 to 100 °C

Results

Use constants in volatilisation form (gas over liquid, H = p/x or C_g/C_l): they rise with temperature for most gases and VOCs. For a solubility-form constant (C_l/p) enter the enthalpy with the opposite sign.

Henry's constant at the required temperature0.26417
Ratio0.62897
Change per kelvin near T₁4.4785%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: TCE 0.42 at 20 C to 10 C groundwater, dH 32 kJ/mol. The inputs, in the units selected above:

InputValue
Henry's constant at the known temperature (any unit; output in the same unit)0.42000 -
Known temperature20.000 °C
Enthalpy change of dissolution (positive for volatilisation)32.000 kJ/mol
Required temperature10.000 °C

Applying the formula below gives:

ResultValue
Henry's constant at the required temperature0.26417
Ratio0.62897
Change per kelvin near T₁4.4785 %

Open this example in the calculator and change any input.

Formula

\(H_2 = H_1\exp\left[\frac{\Delta H^\circ}{R}\left(\frac{1}{T_1} - \frac{1}{T_2}\right)\right]\)

Variables

Symbol Meaning SI unit
\(H_1\) Henry's constant at the known temperature (any unit; output in the same unit) -
\(T_1\) Known temperature K
\(\Delta H^\circ\) Enthalpy change of dissolution (positive for volatilisation) J/mol
\(T_2\) Required temperature K
\(H_2\) Henry's constant at the required temperature -
\(H_2/H_1\) Ratio -
\(\Delta H/\Delta T\) Change per kelvin near T₁ -

Method and standards

Van 't Hoff temperature dependence of Henry's law.

Where it is used

  • Air stripper design at the coldest water temperature.
  • Ozone and oxygen transfer at plant temperatures.

Common mistakes

  • Mixing volatilisation and solubility forms.
  • Using °C instead of kelvin.

Assumptions and limits

  • Constant enthalpy over the temperature range (good within about 0–40 °C).

Questions and answers

Why does it matter for stripping?

A VOC's Henry's constant can halve between 20 and 5 °C, which more than doubles the air needed in winter.

Where do I find ΔH?

From tables of Henry's constants with temperature or by fitting two known values.

What do the defaults represent?

An illustrative case: TCE 0.42 at 20 C to 10 C groundwater, dH 32 kJ/mol. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 14-2, eq. 14-11 and Example 14-2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.