Worked example
Example: TCE 0.42 at 20 C to 10 C groundwater, dH 32 kJ/mol. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Henry's constant at the known temperature (any unit; output in the same unit) | 0.42000 - |
| Known temperature | 20.000 °C |
| Enthalpy change of dissolution (positive for volatilisation) | 32.000 kJ/mol |
| Required temperature | 10.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Henry's constant at the required temperature | 0.26417 |
| Ratio | 0.62897 |
| Change per kelvin near T₁ | 4.4785 % |
Open this example in the calculator and change any input.
Formula
\(H_2 = H_1\exp\left[\frac{\Delta H^\circ}{R}\left(\frac{1}{T_1} - \frac{1}{T_2}\right)\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H_1\) | Henry's constant at the known temperature (any unit; output in the same unit) | - |
| \(T_1\) | Known temperature | K |
| \(\Delta H^\circ\) | Enthalpy change of dissolution (positive for volatilisation) | J/mol |
| \(T_2\) | Required temperature | K |
| \(H_2\) | Henry's constant at the required temperature | - |
| \(H_2/H_1\) | Ratio | - |
| \(\Delta H/\Delta T\) | Change per kelvin near T₁ | - |
Method and standards
Van 't Hoff temperature dependence of Henry's law.
Where it is used
- Air stripper design at the coldest water temperature.
- Ozone and oxygen transfer at plant temperatures.
Common mistakes
- Mixing volatilisation and solubility forms.
- Using °C instead of kelvin.
Assumptions and limits
- Constant enthalpy over the temperature range (good within about 0–40 °C).
Questions and answers
Why does it matter for stripping?
A VOC's Henry's constant can halve between 20 and 5 °C, which more than doubles the air needed in winter.
Where do I find ΔH?
From tables of Henry's constants with temperature or by fitting two known values.
What do the defaults represent?
An illustrative case: TCE 0.42 at 20 C to 10 C groundwater, dH 32 kJ/mol. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 14-2, eq. 14-11 and Example 14-2