DAF Saturator Air and Bubble Concentration in the Contact Zone

Air dissolved in the DAF saturator by Henry's law, air released in the contact zone, bubble volume and number concentrations and bubble-to-floc ratios.

Inputs

Examples: Cold water (4 C), 500 kPa, 8 % recycle, 50 um bubblesWarm water (30 C), 650 kPa, 12 % recycle

Accepted: 120 to 1,200 kPa
Accepted: 0 to 40 °C
Accepted: 1 to 1,000,000
Accepted: 0 to 100 kJ/mol
Accepted: 1 to 100 %
Accepted: 10 to 100 %
Accepted: 0 to 50 mg/L
Accepted: 5 to 200 µm
Accepted: 1 to 10,000,000
Accepted: 0.001 to 100,000

Results

Henry's law with H_YC = K_C exp(−ΔH/RT) (air: K_C 3368, ΔH 10.28 kJ/mol); dry-air density at 1 atm. Air released C_b = [e(C_r − C_fl)r − k]/(1 + r) with the flocculated water saturated at 1 atm less its deficit k (Edzwald's white-water model).

Air density at 1 atm and T1.2736kg/m³
Dimensionless Henry's constant38.898
Air in water saturated at 1 atm32.742mg/L
Air in the saturated recycle161.57mg/L
Air released in the contact zone7.1855mg/L
Bubble volume concentration, ppm5,641.8
Bubble number concentration, bubbles/mL86,200
Bubbles per floc particle21.550
Bubble-to-floc volume ratio1,128.4

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Cold water (4 C), 500 kPa, 8 % recycle, 50 um bubbles. The inputs, in the units selected above:

InputValue
Saturator absolute pressure500.00 kPa
Water temperature4.0000 °C
Henry's constant coefficient for air3,368.0 -
Enthalpy of dissolution for air10.280 kJ/mol
Recycle ratio8.0000 %
Saturator-to-release transfer efficiency85.000 %
Air deficit of the flocculated water1.0000 mg/L
Mean bubble diameter50.000 µm
Floc particle concentration, particles/mL4,000.0 -
Floc volume concentration, ppm (mL/m³)5.0000 -

Applying the formula below gives:

ResultValue
Air density at 1 atm and T1.2736 kg/m³
Dimensionless Henry's constant38.898
Air in water saturated at 1 atm32.742 mg/L
Air in the saturated recycle161.57 mg/L
Air released in the contact zone7.1855 mg/L
Bubble volume concentration, ppm5,641.8
Bubble number concentration, bubbles/mL86,200
Bubbles per floc particle21.550
Bubble-to-floc volume ratio1,128.4

Open this example in the calculator and change any input.

Formula

\(H_{YC} = K_C\exp\left(-\frac{\Delta H_{dis}}{RT}\right), \quad C_{fl} = \frac{\rho_{air}}{H_{YC}}, \quad C_r = C_{fl}\frac{P_{sat}}{P_{atm}}\)

\(C_b = \frac{e(C_r - C_{fl})r - k}{1 + r}, \quad \phi_b = \frac{C_b}{\rho_{air}}, \quad N_b = \frac{6\phi_b}{\pi d_b^3}\)

Variables

Symbol Meaning SI unit
\(P_{sat}\) Saturator absolute pressure Pa
\(T\) Water temperature K
\(K_C\) Henry's constant coefficient for air -
\(\Delta H_{dis}\) Enthalpy of dissolution for air J/mol
\(r\) Recycle ratio -
\(e\) Saturator-to-release transfer efficiency -
\(k\) Air deficit of the flocculated water kg/m³
\(d_b\) Mean bubble diameter m
\(N_p\) Floc particle concentration, particles/mL -
\(\phi_p\) Floc volume concentration, ppm (mL/m³) -
\(\rho_{air}\) Air density at 1 atm and T kg/m³
\(H_{YC}\) Dimensionless Henry's constant -
\(C_{fl}\) Air in water saturated at 1 atm kg/m³
\(C_r\) Air in the saturated recycle kg/m³
\(C_b\) Air released in the contact zone kg/m³
\(\phi_b\) Bubble volume concentration, ppm -
\(N_b\) Bubble number concentration, bubbles/mL -
\(N_b/N_p\) Bubbles per floc particle -
\(\phi_b/\phi_p\) Bubble-to-floc volume ratio -

Method and standards

Henry's-law saturation and an air mass balance on the DAF contact zone.

Where it is used

  • DAF design and recycle selection.
  • Checking performance in warm water.

Common mistakes

  • Using gauge pressure in Henry's law.
  • Forgetting the oxygen deficit of the flocculated water.

Assumptions and limits

  • Equilibrium saturation scaled linearly with pressure; air treated as one gas.

Questions and answers

Why does warm water need more recycle?

Air solubility falls with temperature (35.6 mg/L at 0 °C against 24.3 mg/L at 20 °C at 1 atm), so less air is carried per litre of recycle.

What do the defaults represent?

An illustrative case: Cold water (4 C), 500 kPa, 8 % recycle, 50 um bubbles. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 10-9, eqs. 10-48 to 10-50, 14-11 and 14-25 and Examples 10-9 and 10-10 (after Edzwald 2010; Gregory et al. 1999)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.