Worked example
Example: Cold water (4 C), 500 kPa, 8 % recycle, 50 um bubbles. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Saturator absolute pressure | 500.00 kPa |
| Water temperature | 4.0000 °C |
| Henry's constant coefficient for air | 3,368.0 - |
| Enthalpy of dissolution for air | 10.280 kJ/mol |
| Recycle ratio | 8.0000 % |
| Saturator-to-release transfer efficiency | 85.000 % |
| Air deficit of the flocculated water | 1.0000 mg/L |
| Mean bubble diameter | 50.000 µm |
| Floc particle concentration, particles/mL | 4,000.0 - |
| Floc volume concentration, ppm (mL/m³) | 5.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Air density at 1 atm and T | 1.2736 kg/m³ |
| Dimensionless Henry's constant | 38.898 |
| Air in water saturated at 1 atm | 32.742 mg/L |
| Air in the saturated recycle | 161.57 mg/L |
| Air released in the contact zone | 7.1855 mg/L |
| Bubble volume concentration, ppm | 5,641.8 |
| Bubble number concentration, bubbles/mL | 86,200 |
| Bubbles per floc particle | 21.550 |
| Bubble-to-floc volume ratio | 1,128.4 |
Open this example in the calculator and change any input.
Formula
\(H_{YC} = K_C\exp\left(-\frac{\Delta H_{dis}}{RT}\right), \quad C_{fl} = \frac{\rho_{air}}{H_{YC}}, \quad C_r = C_{fl}\frac{P_{sat}}{P_{atm}}\)
\(C_b = \frac{e(C_r - C_{fl})r - k}{1 + r}, \quad \phi_b = \frac{C_b}{\rho_{air}}, \quad N_b = \frac{6\phi_b}{\pi d_b^3}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P_{sat}\) | Saturator absolute pressure | Pa |
| \(T\) | Water temperature | K |
| \(K_C\) | Henry's constant coefficient for air | - |
| \(\Delta H_{dis}\) | Enthalpy of dissolution for air | J/mol |
| \(r\) | Recycle ratio | - |
| \(e\) | Saturator-to-release transfer efficiency | - |
| \(k\) | Air deficit of the flocculated water | kg/m³ |
| \(d_b\) | Mean bubble diameter | m |
| \(N_p\) | Floc particle concentration, particles/mL | - |
| \(\phi_p\) | Floc volume concentration, ppm (mL/m³) | - |
| \(\rho_{air}\) | Air density at 1 atm and T | kg/m³ |
| \(H_{YC}\) | Dimensionless Henry's constant | - |
| \(C_{fl}\) | Air in water saturated at 1 atm | kg/m³ |
| \(C_r\) | Air in the saturated recycle | kg/m³ |
| \(C_b\) | Air released in the contact zone | kg/m³ |
| \(\phi_b\) | Bubble volume concentration, ppm | - |
| \(N_b\) | Bubble number concentration, bubbles/mL | - |
| \(N_b/N_p\) | Bubbles per floc particle | - |
| \(\phi_b/\phi_p\) | Bubble-to-floc volume ratio | - |
Method and standards
Henry's-law saturation and an air mass balance on the DAF contact zone.
Where it is used
- DAF design and recycle selection.
- Checking performance in warm water.
Common mistakes
- Using gauge pressure in Henry's law.
- Forgetting the oxygen deficit of the flocculated water.
Assumptions and limits
- Equilibrium saturation scaled linearly with pressure; air treated as one gas.
Questions and answers
Why does warm water need more recycle?
Air solubility falls with temperature (35.6 mg/L at 0 °C against 24.3 mg/L at 20 °C at 1 atm), so less air is carried per litre of recycle.
What do the defaults represent?
An illustrative case: Cold water (4 C), 500 kPa, 8 % recycle, 50 um bubbles. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 10-9, eqs. 10-48 to 10-50, 14-11 and 14-25 and Examples 10-9 and 10-10 (after Edzwald 2010; Gregory et al. 1999)