FireCADCalc

River Oxygen Sag by Streeter–Phelps

Critical time, distance and dissolved oxygen deficit below a wastewater discharge into a river, from BOD, initial deficit and deoxygenation and reaeration rates.

Inputs

Examples: Illustrative river below an outfallSluggish warm riverFast stream, little sag

Accepted: 0.1 to 1,000 mg/L
Accepted: 0 to 20 mg/L
Accepted: 0.01 to 5 1/d
Accepted: 0.01 to 50 1/d
Accepted: 4 to 15 mg/L
Accepted: 0.01 to 5 m/s

Results

Downstream of a discharge, BOD exertion (k₁L) uses oxygen while reaeration (k₂D) restores it; the deficit rises to a maximum at the critical time and then recovers. The critical point is where the two rates balance, D_c = (k₁/k₂)L₀e^(−k₁t_c). Rates must be at the river temperature (k₁ about 0.1–0.4 per day; k₂ from 0.1 for sluggish rivers to over 1 for rapids, e.g. by O'Connor–Dobbins 3.9u^0.5/H^1.5). Compare the minimum DO with the standard for the river's use.

Critical time2.6520d
Critical distance68.740km
Critical (maximum) deficit4.9990mg/L
Minimum dissolved oxygen4.1010mg/L
Self-purification factor k₂/k₁2.1739

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative river below an outfall. The inputs, in the units selected above:

InputValue
Ultimate BOD of the mixed river water20.000 mg/L
Initial oxygen deficit1.0000 mg/L
Deoxygenation rate (base e)0.23000 1/d
Reaeration rate (base e)0.50000 1/d
Saturation dissolved oxygen9.1000 mg/L
River velocity0.30000 m/s

Applying the formula below gives:

ResultValue
Critical time2.6520 d
Critical distance68.740 km
Critical (maximum) deficit4.9990 mg/L
Minimum dissolved oxygen4.1010 mg/L
Self-purification factor k₂/k₁2.1739

Open this example in the calculator and change any input.

Formula

\(t_c = \frac{1}{k_2 - k_1}\ln\left[\frac{k_2}{k_1}\left(1 - \frac{D_0(k_2 - k_1)}{k_1L_0}\right)\right], \quad D_c = \frac{k_1}{k_2}L_0e^{-k_1t_c}\)

Variables

Symbol Meaning SI unit
\(L_0\) Ultimate BOD of the mixed river water kg/m³
\(D_0\) Initial oxygen deficit kg/m³
\(k_1\) Deoxygenation rate (base e) 1/s
\(k_2\) Reaeration rate (base e) 1/s
\(C_s\) Saturation dissolved oxygen kg/m³
\(u\) River velocity m/s
\(t_c\) Critical time s
\(x_c\) Critical distance m
\(D_c\) Critical (maximum) deficit kg/m³
\(DO_{min}\) Minimum dissolved oxygen kg/m³
\(f\) Self-purification factor k₂/k₁ -

Method and standards

Oxygen sag.

Where it is used

  • Discharge consent studies.
  • Environmental engineering examinations.

Common mistakes

  • Using base-10 rate constants in base-e equations.
  • Using rates at 20 °C for a warm river.

Assumptions and limits

  • Single point discharge; steady uniform flow.

Questions and answers

Where does the oxygen sag bottom out for the defaults?

After about 2.65 days, 69 km downstream, at a deficit of 5.0 mg/L (DO 4.1 mg/L).

What raises the minimum DO?

Less BOD discharged, or faster reaeration (shallower, faster flow).

What do the defaults represent?

An illustrative river with mixed ultimate BOD 20 mg/L, initial deficit 1 mg/L, k₁ 0.23 and k₂ 0.5 per day, saturation 9.1 mg/L, flowing at 0.3 m/s.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Streeter and Phelps, A study of the pollution and natural purification of the Ohio River, US Public Health Service Bulletin 146 (1925)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.