Worked example
Example: Illustrative loam: K 6.5 mm/h, psi 110 mm, deficit 0.30, ponded, 1 h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Saturated hydraulic conductivity | 6.5000 mm/h |
| Wetting front suction head | 110.00 mm |
| Moisture deficit (porosity minus initial content) | 30.000 % |
| Time | 1.0000 h |
| Rainfall intensity (0 for ponded from the start) | 0 mm/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Cumulative infiltration | 25.254 mm |
| Infiltration rate | 14.994 mm/h |
| Ponding time (0 if ponded from the start) | 0 h |
| Infiltration at ponding | 0 mm |
Open this example in the calculator and change any input.
Formula
\(F - \psi\Delta\theta\ln\left(1 + \frac{F}{\psi\Delta\theta}\right) = Kt, \quad f = K\left(1 + \frac{\psi\Delta\theta}{F}\right), \quad t_p = \frac{K\psi\Delta\theta}{i(i - K)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(K\) | Saturated hydraulic conductivity | m/s |
| \(\psi\) | Wetting front suction head | m |
| \(\Delta\theta\) | Moisture deficit (porosity minus initial content) | - |
| \(t\) | Time | s |
| \(i\) | Rainfall intensity (0 for ponded from the start) | m/s |
| \(F\) | Cumulative infiltration | m |
| \(f\) | Infiltration rate | m/s |
| \(t_p\) | Ponding time (0 if ponded from the start) | s |
| \(F_p\) | Infiltration at ponding | m |
Method and standards
Physically based infiltration model.
Where it is used
- Runoff and flood modelling, drainage design.
- Irrigation and soil water studies.
Common mistakes
- Using the total porosity instead of the moisture deficit.
- Ignoring ponding time under light rain.
Assumptions and limits
- Homogeneous soil, sharp wetting front, ponded water depth negligible.
References
- Green–Ampt infiltration with the Mein–Larson ponding time
Questions and answers
Where do the soil parameters come from?
Rawls and Brakensiek tabulated K, ψ and porosity by soil texture; for a silt loam K ≈ 6.5 mm/h and ψ ≈ 170 mm, for a sandy loam K ≈ 11 mm/h and ψ ≈ 110 mm.
What is the ponding time?
Under steady rain heavier than K, the time when the soil can no longer absorb all the rain and water starts to pond and run off.
What do the defaults represent?
An illustrative loam (K 6.5 mm/h, suction 110 mm, moisture deficit 0.30) ponded from the start, after one hour.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Chow, Maidment and Mays, Applied Hydrology (McGraw-Hill, 1988), sec. 4.3 and 4.4