FireCADCalc

Culvert Headwater under Inlet and Outlet Control

Headwater depth of a circular culvert for a design flow under inlet control (orifice) and outlet control (full-flow losses), and which control governs.

Inputs

Examples: Illustrative 1.2 m pipe, 2.5 m3/sLong flat 0.9 m pipeCorrugated 1.8 m, steep

Accepted: 36 to 1,800,000 m³/h
Accepted: 300 to 6,000 mm
Accepted: 1 to 500 m
Accepted: 0 to 20 %
Accepted: 0.009 to 0.035
Accepted: 0.1 to 1
Accepted: 0.4 to 1
Accepted: 0 to 10 m

Results

Inlet control: submerged orifice at mid-height; outlet control: full flow with entrance, friction and exit losses from max(TW, D) at the outlet. The larger headwater governs. Unsubmerged inlets (HW below about 1.2D) act as weirs; use the full charts for those.

Outlet control governs.

Full-pipe velocity2.2105m/s
Headwater, inlet control1.2920m
Headwater, outlet control1.3970m
Design headwater1.3970m
Headwater to diameter ratio1.1642

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1.2 m pipe, 2.5 m3/s. The inputs, in the units selected above:

InputValue
Design flow9,000.0 m³/h
Pipe diameter1,200.0 mm
Culvert length30.000 m
Culvert slope1.0000 %
Manning roughness0.013000 -
Entrance loss coefficient0.50000 -
Inlet orifice coefficient0.60000 -
Tailwater depth above outlet invert0.80000 m

Applying the formula below gives:

ResultValue
Full-pipe velocity2.2105 m/s
Headwater, inlet control1.2920 m
Headwater, outlet control1.3970 m
Design headwater1.3970 m
Headwater to diameter ratio1.1642

Open this example in the calculator and change any input.

Formula

\(HW_i = \frac{Q^2}{2gC_d^2A^2} + \frac D2, \quad HW_o = \max(TW, D) + \left(1 + k_e + \frac{2gn^2L}{R^{4/3}}\right)\frac{V^2}{2g} - S_0L\)

Variables

Symbol Meaning SI unit
\(Q\) Design flow m³/s
\(D\) Pipe diameter m
\(L\) Culvert length m
\(S_0\) Culvert slope -
\(n\) Manning roughness -
\(k_e\) Entrance loss coefficient -
\(C_d\) Inlet orifice coefficient -
\(TW\) Tailwater depth above outlet invert m
\(V\) Full-pipe velocity m/s
\(HW_i\) Headwater, inlet control m
\(HW_o\) Headwater, outlet control m
\(HW\) Design headwater m
\(HW/D\) Headwater to diameter ratio -

Method and standards

Culvert control.

Where it is used

  • Road and rail drainage.
  • Checking existing culverts for higher flows.

Common mistakes

  • Checking only one control.
  • Using unsubmerged inlets with the orifice formula.

Assumptions and limits

  • Circular pipe; submerged inlet; steady flow.

References

  • Culvert hydraulics
  • inlet and outlet control

Questions and answers

What headwater is acceptable?

Often HW/D up to about 1.2–1.5, limited by road level and upstream flooding.

Why does outlet control depend on length?

Friction loss grows with length; long culverts on flat slopes are usually outlet-controlled.

What do the defaults represent?

An illustrative 1.2 m concrete pipe culvert, 30 m long on a 1 % slope, carrying 2.5 m³/s with 0.8 m tailwater.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Chow, Open-Channel Hydraulics (McGraw-Hill, 1959)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.