FireCADCalc

Reference Evapotranspiration ET₀ (FAO-56 Penman–Monteith)

Daily reference crop evapotranspiration by the FAO-56 Penman–Monteith equation from temperatures, humidity, wind, solar radiation, altitude, latitude and date.

Sugar mill and cogeneration

Inputs

Examples: Illustrative: 18 N, 300 m, day 120, 33/21 C, RH 80/35 %, 2.5 m/s, 24 MJ/m2dHumid monsoon day: 13 N, 30/24 C, RH 95/75 %, 1.5 m/s, 15 MJ/m2d, day 200

Accepted: -43.15 to 56.85 °C
Accepted: -53.15 to 46.85 °C
Accepted: 1 to 100 %
Accepted: 1 to 100 %
Accepted: 0 to 30 m/s
Accepted: 0 to 43.2 MJ/(m²·d)
Accepted: -400 to 5,000 m
Accepted: -68.755 to 68.755 °
Accepted: 1 to 366

Results

FAO-56 daily Penman–Monteith for a 0.12 m grass reference crop (albedo 0.23), soil heat flux neglected for daily steps. Crop water use is ET₀ times the crop coefficient K_c.

Reference evapotranspiration6.4147mm/d
Extraterrestrial radiation38.708MJ/(m²·d)
Net radiation14.000MJ/(m²·d)
Vapour pressure deficit1.8835kPa
Slope of the vapour pressure curve0.20916
Psychrometric constant (kPa/°C)0.065039

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 18 N, 300 m, day 120, 33/21 C, RH 80/35 %, 2.5 m/s, 24 MJ/m2d. The inputs, in the units selected above:

InputValue
Maximum air temperature33.000 °C
Minimum air temperature21.000 °C
Maximum relative humidity80.000 %
Minimum relative humidity35.000 %
Mean wind speed at 2 m2.5000 m/s
Solar radiation24.000 MJ/(m²·d)
Altitude above sea level300.00 m
Latitude (south negative)18.000 °
Day of the year (1–366)120.00 -

Applying the formula below gives:

ResultValue
Reference evapotranspiration6.4147 mm/d
Extraterrestrial radiation38.708 MJ/(m²·d)
Net radiation14.000 MJ/(m²·d)
Vapour pressure deficit1.8835 kPa
Slope of the vapour pressure curve0.20916
Psychrometric constant (kPa/°C)0.065039

Open this example in the calculator and change any input.

Formula

\(ET_0 = \frac{0.408\Delta(R_n - G) + \gamma\frac{900}{T + 273}u_2(e_s - e_a)}{\Delta + \gamma(1 + 0.34u_2)}\)

Variables

Symbol Meaning SI unit
\(T_{max}\) Maximum air temperature K
\(T_{min}\) Minimum air temperature K
\(RH_{max}\) Maximum relative humidity -
\(RH_{min}\) Minimum relative humidity -
\(u_2\) Mean wind speed at 2 m m/s
\(R_s\) Solar radiation W/m²
\(z\) Altitude above sea level m
\(\varphi\) Latitude (south negative) rad
\(J\) Day of the year (1–366) -
\(ET_0\) Reference evapotranspiration m/s
\(R_a\) Extraterrestrial radiation W/m²
\(R_n\) Net radiation W/m²
\(e_s - e_a\) Vapour pressure deficit Pa
\(\Delta\) Slope of the vapour pressure curve -
\(\gamma\) Psychrometric constant (kPa/°C) -

Method and standards

FAO-56 Penman–Monteith equation.

Where it is used

  • Irrigation scheduling and crop water requirements.
  • Water balance of reservoirs, catchments and treatment wetlands.

Common mistakes

  • Using mean humidity with T_max and T_min swapped.
  • Forgetting to convert ET₀ to crop ET with K_c.

Assumptions and limits

  • Daily time step, well-watered reference grass, weather measured at 2 m.

References

  • FAO-56 Penman–Monteith reference evapotranspiration

Questions and answers

What is the reference crop?

A hypothetical well-watered grass 0.12 m tall with a surface resistance of 70 s/m and an albedo of 0.23; actual crops use ET_c = K_c × ET₀.

What if I have sunshine hours instead of radiation?

Estimate R_s by the Ångström formula R_s = (0.25 + 0.50 n/N)R_a; with no data, FAO-56 gives a temperature-based estimate.

What do the defaults represent?

An illustrative hot dry-season day at 18° N and 300 m altitude, end of April: 33/21 °C, humidity 80/35 %, wind 2.5 m/s and 24 MJ/(m²·d) of sunshine.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Allen, Pereira, Raes and Smith, Crop Evapotranspiration, FAO Irrigation and Drainage Paper 56 (FAO, 1998), ch. 2–4

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.