Worked example
Example: Illustrative: 12 m3/s in a 4 m channel at 0.6 m (supercritical). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Discharge | 12.000 m³/s |
| Channel width | 4.0000 m |
| Known depth | 0.60000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Discharge per unit width | 3.0000 m³/(s·m) |
| Specific energy y + q²/(2gy²) | 1.8746 m |
| Critical depth | 0.97179 m |
| Minimum specific energy 1.5 y_c | 1.4577 m |
| Alternate depth with the same energy | 1.7194 m |
| Froude number at y₁ | 2.0613 |
| Froude number at y₂ | 0.42490 |
Open this example in the calculator and change any input.
Formula
\(E = y + \frac{q^2}{2gy^2}, \quad y_c = \left(\frac{q^2}{g}\right)^{1/3}, \quad E_{min} = \frac{3}{2}y_c, \quad Fr = \frac{q}{y\sqrt{gy}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Discharge | m³/s |
| \(b\) | Channel width | m |
| \(y_1\) | Known depth | m |
| \(q\) | Discharge per unit width | m³/(s·m) |
| \(E\) | Specific energy y + q²/(2gy²) | m |
| \(y_c\) | Critical depth | m |
| \(E_{min}\) | Minimum specific energy 1.5 y_c | m |
| \(y_2\) | Alternate depth with the same energy | m |
| \(Fr_1\) | Froude number at y₁ | - |
| \(Fr_2\) | Froude number at y₂ | - |
Method and standards
Specific energy concept.
Where it is used
- Flow under gates, over steps and through contractions.
- Channel transitions and flumes.
Common mistakes
- Confusing alternate depths with sequent depths.
- Applying it to non-rectangular sections without the area terms.
Assumptions and limits
- Rectangular channel, hydrostatic pressure, uniform velocity.
References
- Specific energy and alternate depths
Questions and answers
What are alternate depths?
For a given discharge and energy there are two possible depths: a deep slow subcritical one and a shallow fast supercritical one.
Is the alternate depth the same as the sequent (jump) depth?
No: alternate depths share energy; sequent depths share momentum. A hydraulic jump loses energy, so its downstream depth is less than the alternate depth.
What do the defaults represent?
An illustrative 4 m wide channel carrying 12 m³/s at a shallow 0.6 m depth.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Chow, Open-Channel Hydraulics (McGraw-Hill, 1959), ch. 3