Sewer Self-Cleansing Velocity and Minimum Slope (Camp)

Velocity and slope that keep a grit particle moving in a sewer by Camp's critical shear relation, and the full-bore flow at that slope.

Inputs

Examples: Illustrative 300 mm sewer, 1 mm gritLarge storm sewer 1.2 mScouring deposits, k = 0.8

Accepted: 50 to 5,000 mm
Accepted: 0.008 to 0.03
Accepted: 0.01 to 1
Accepted: 1.01 to 5
Accepted: 0.01 to 20 mm

Results

A deposit stays moving while the bed shear stress ρgRS exceeds kρg(G_s − 1)d, so the self-cleansing slope is S = k(G_s − 1)d/R and, with Manning's equation, V = (1/n)R^(1/6)√[k(G_s − 1)d] (Camp, after Shields). k ≈ 0.04 starts motion of clean grit and 0.8 is needed to scour sticky deposits; 0.06 is commonly used for sanitary sewers. A circular pipe running full or half full has R = D/4, so the velocity is the same in both. Typical design minima are 0.6 m/s for sanitary and 0.9 m/s for storm sewers.

Hydraulic radius D/475.000mm
Self-cleansing velocity0.49703m/s
Minimum slope0.001320
Full-bore flow at that slope35.133L/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 300 mm sewer, 1 mm grit. The inputs, in the units selected above:

InputValue
Pipe diameter (running full or half full)300.00 mm
Manning roughness0.013000 -
Dimensionless constant (0.04 start of motion to 0.8 scour)0.060000 -
Specific gravity of the particle2.6500 -
Particle diameter1.0000 mm

Applying the formula below gives:

ResultValue
Hydraulic radius D/475.000 mm
Self-cleansing velocity0.49703 m/s
Minimum slope0.001320
Full-bore flow at that slope35.133 L/s

Open this example in the calculator and change any input.

Formula

\(S = \frac{k(G_s - 1)d}{R}, \quad V_s = \frac1nR^{1/6}\sqrt{k(G_s - 1)d}\)

Variables

Symbol Meaning SI unit
\(D\) Pipe diameter (running full or half full) m
\(n\) Manning roughness -
\(k\) Dimensionless constant (0.04 start of motion to 0.8 scour) -
\(G_s\) Specific gravity of the particle -
\(d\) Particle diameter m
\(R\) Hydraulic radius D/4 m
\(V_s\) Self-cleansing velocity m/s
\(S_{min}\) Minimum slope -
\(Q\) Full-bore flow at that slope m³/s

Method and standards

Self-cleansing.

Where it is used

  • Sewer gradient design.
  • Checking flat sewers for deposits.

Common mistakes

  • Using velocity alone for very large sewers (shear stress governs).
  • Taking k for clean grit where fats and rags bind deposits.

Assumptions and limits

  • Uniform flow; circular pipe full or half full; non-cohesive particle.

References

  • Camp's self-cleansing velocity

Questions and answers

Why is the velocity the same full and half full?

A circular pipe has R = D/4 in both states, so slope and velocity are the same.

What k should I use?

About 0.04–0.06 for clean grit; up to 0.8 to scour deposits that have consolidated.

What do the defaults represent?

An illustrative 300 mm concrete sewer (n = 0.013) moving 1 mm grit of G_s = 2.65 with k = 0.06.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Camp, Sedimentation and the Design of Settling Tanks, Trans. ASCE 111 (1946); Metcalf and Eddy, Wastewater Engineering, 5th ed. (McGraw-Hill, 2014)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.