Worked example
Example: Illustrative river below an outfall. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Ultimate BOD of the mixed river water | 20.000 mg/L |
| Initial oxygen deficit | 1.0000 mg/L |
| Deoxygenation rate (base e) | 0.23000 1/d |
| Reaeration rate (base e) | 0.50000 1/d |
| Saturation dissolved oxygen | 9.1000 mg/L |
| River velocity | 0.30000 m/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Critical time | 2.6520 d |
| Critical distance | 68.740 km |
| Critical (maximum) deficit | 4.9990 mg/L |
| Minimum dissolved oxygen | 4.1010 mg/L |
| Self-purification factor k₂/k₁ | 2.1739 |
Open this example in the calculator and change any input.
Formula
\(t_c = \frac{1}{k_2 - k_1}\ln\left[\frac{k_2}{k_1}\left(1 - \frac{D_0(k_2 - k_1)}{k_1L_0}\right)\right], \quad D_c = \frac{k_1}{k_2}L_0e^{-k_1t_c}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L_0\) | Ultimate BOD of the mixed river water | kg/m³ |
| \(D_0\) | Initial oxygen deficit | kg/m³ |
| \(k_1\) | Deoxygenation rate (base e) | 1/s |
| \(k_2\) | Reaeration rate (base e) | 1/s |
| \(C_s\) | Saturation dissolved oxygen | kg/m³ |
| \(u\) | River velocity | m/s |
| \(t_c\) | Critical time | s |
| \(x_c\) | Critical distance | m |
| \(D_c\) | Critical (maximum) deficit | kg/m³ |
| \(DO_{min}\) | Minimum dissolved oxygen | kg/m³ |
| \(f\) | Self-purification factor k₂/k₁ | - |
Method and standards
Oxygen sag.
Where it is used
- Discharge consent studies.
- Environmental engineering examinations.
Common mistakes
- Using base-10 rate constants in base-e equations.
- Using rates at 20 °C for a warm river.
Assumptions and limits
- Single point discharge; steady uniform flow.
Questions and answers
Where does the oxygen sag bottom out for the defaults?
After about 2.65 days, 69 km downstream, at a deficit of 5.0 mg/L (DO 4.1 mg/L).
What raises the minimum DO?
Less BOD discharged, or faster reaeration (shallower, faster flow).
What do the defaults represent?
An illustrative river with mixed ultimate BOD 20 mg/L, initial deficit 1 mg/L, k₁ 0.23 and k₂ 0.5 per day, saturation 9.1 mg/L, flowing at 0.3 m/s.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Streeter and Phelps, A study of the pollution and natural purification of the Ohio River, US Public Health Service Bulletin 146 (1925)