FireCADCalc

Bridge Pier Local Scour Depth (CSU / HEC-18)

Local scour depth at a bridge pier from its width, length, attack angle, flow depth and velocity by the Colorado State University equation used in HEC-18.

Inputs

Examples: Illustrative round pier at 10 degreesAligned square pierSharp-nosed pier, shallow flow

Accepted: 0.1 to 20 m
Accepted: 0.1 to 100 m
Accepted: 0 to 90 °
Accepted: 0.1 to 50 m
Accepted: 0.05 to 10 m/s
1.1 for clear-water, plane bed and small dunes; up to 1.3 for large dunes.Accepted: 1 to 1.3

Results

The CSU equation y_s = 2.0 K₁K₂K₃ a (y₁/a)^0.35 Fr₁^0.43 gives the equilibrium local scour at a pier. A skewed pier presents a wider face: K₂ = (cos θ + (L/a) sin θ)^0.65 with L/a no more than 12; when the attack angle exceeds 5° the nose-shape factor K₁ is taken as 1.0. For round-nosed piers aligned with the flow HEC-18 caps the scour at 2.4a (Froude ≤ 0.8) or 3.0a. Add contraction scour and long-term degradation for the total scour depth.

Froude number upstream0.31933
Angle of attack factor1.6409
Local scour depth4.0414m
Scour depth relative to pier width3.3678

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative round pier at 10 degrees. The inputs, in the units selected above:

InputValue
Pier width1.2000 m
Pier length8.0000 m
Angle of attack of the flow10.000 °
Flow depth just upstream4.0000 m
Mean velocity just upstream2.0000 m/s
Pier nose shapeRound nose or cylinder (1.0)
Bed condition factor1.1000 -

Applying the formula below gives:

ResultValue
Froude number upstream0.31933
Angle of attack factor1.6409
Local scour depth4.0414 m
Scour depth relative to pier width3.3678

Open this example in the calculator and change any input.

Formula

\(\frac{y_s}{a} = 2.0K_1K_2K_3\left(\frac{y_1}{a}\right)^{0.35} Fr_1^{0.43}, \quad K_2 = \left(\cos\theta + \frac La\sin\theta\right)^{0.65}\)

Variables

Symbol Meaning SI unit
\(a\) Pier width m
\(L\) Pier length m
\(\theta\) Angle of attack of the flow rad
\(y_1\) Flow depth just upstream m
\(V_1\) Mean velocity just upstream m/s
\(K_1\) Pier nose shape -
\(K_3\) Bed condition factor -
\(Fr_1\) Froude number upstream -
\(K_2\) Angle of attack factor -
\(y_s\) Local scour depth m
\(y_s/a\) Scour depth relative to pier width -

Method and standards

Pier scour.

Where it is used

  • Bridge foundation depth.
  • Scour assessment of existing bridges.

Common mistakes

  • Omitting the skew factor.
  • Taking local scour as the total scour.

Assumptions and limits

  • Non-cohesive bed; equilibrium scour; no debris.

References

  • Colorado State University pier scour equation

Questions and answers

How deep can scour at a pier be?

Typically 1.5–2.5 times the pier width for aligned piers; skewed piers scour much deeper.

Why does skew matter so much?

A long pier at an angle presents a much wider obstruction: K₂ can exceed 2 at 15–30°.

What do the defaults represent?

An illustrative 1.2 m wide, 8 m long round-nosed pier at 10° to a 4 m deep flow at 2 m/s.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

FHWA Hydraulic Engineering Circular No. 18, Evaluating Scour at Bridges, 5th ed. (2012)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.