Worked example
Example: Illustrative round pier at 10 degrees. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pier width | 1.2000 m |
| Pier length | 8.0000 m |
| Angle of attack of the flow | 10.000 ° |
| Flow depth just upstream | 4.0000 m |
| Mean velocity just upstream | 2.0000 m/s |
| Pier nose shape | Round nose or cylinder (1.0) |
| Bed condition factor | 1.1000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Froude number upstream | 0.31933 |
| Angle of attack factor | 1.6409 |
| Local scour depth | 4.0414 m |
| Scour depth relative to pier width | 3.3678 |
Open this example in the calculator and change any input.
Formula
\(\frac{y_s}{a} = 2.0K_1K_2K_3\left(\frac{y_1}{a}\right)^{0.35} Fr_1^{0.43}, \quad K_2 = \left(\cos\theta + \frac La\sin\theta\right)^{0.65}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(a\) | Pier width | m |
| \(L\) | Pier length | m |
| \(\theta\) | Angle of attack of the flow | rad |
| \(y_1\) | Flow depth just upstream | m |
| \(V_1\) | Mean velocity just upstream | m/s |
| \(K_1\) | Pier nose shape | - |
| \(K_3\) | Bed condition factor | - |
| \(Fr_1\) | Froude number upstream | - |
| \(K_2\) | Angle of attack factor | - |
| \(y_s\) | Local scour depth | m |
| \(y_s/a\) | Scour depth relative to pier width | - |
Method and standards
Pier scour.
Where it is used
- Bridge foundation depth.
- Scour assessment of existing bridges.
Common mistakes
- Omitting the skew factor.
- Taking local scour as the total scour.
Assumptions and limits
- Non-cohesive bed; equilibrium scour; no debris.
References
- Colorado State University pier scour equation
Questions and answers
How deep can scour at a pier be?
Typically 1.5–2.5 times the pier width for aligned piers; skewed piers scour much deeper.
Why does skew matter so much?
A long pier at an angle presents a much wider obstruction: K₂ can exceed 2 at 15–30°.
What do the defaults represent?
An illustrative 1.2 m wide, 8 m long round-nosed pier at 10° to a 4 m deep flow at 2 m/s.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
FHWA Hydraulic Engineering Circular No. 18, Evaluating Scour at Bridges, 5th ed. (2012)