Worked example
Example: Illustrative: 600 mm sewer, n 0.013, slope 0.4 %, 360 mm deep. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pipe internal diameter | 600.00 mm |
| Flow depth | 360.00 mm |
| Pipe slope | 0.40000 % |
| Manning roughness | 0.013000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Central angle subtended by the water surface | 203.07 ° |
| Flow area | 0.17713 m² |
| Wetted perimeter | 1.0633 m |
| Hydraulic radius | 166.59 mm |
| Velocity | 1.4729 m/s |
| Discharge | 260.90 L/s |
| Discharge relative to full | 67.184 % |
| Velocity relative to full | 107.24 % |
Open this example in the calculator and change any input.
Formula
\(\theta = 2\cos^{-1}\left(1 - \frac{2y}{D}\right), \quad A = \frac{D^2}{8}(\theta - \sin\theta), \quad P = \frac{D\theta}{2}, \quad V = \frac{1}{n}R^{2/3}S^{1/2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Pipe internal diameter | m |
| \(y\) | Flow depth | m |
| \(S\) | Pipe slope | - |
| \(n\) | Manning roughness | - |
| \(\theta\) | Central angle subtended by the water surface | rad |
| \(A\) | Flow area | m² |
| \(P\) | Wetted perimeter | m |
| \(R\) | Hydraulic radius | m |
| \(V\) | Velocity | m/s |
| \(Q\) | Discharge | m³/s |
| \(Q/Q_{full}\) | Discharge relative to full | - |
| \(V/V_{full}\) | Velocity relative to full | - |
Method and standards
Circular-segment geometry with Manning's equation.
Where it is used
- Sewer and storm drain design and checks.
- Culverts flowing part full.
Common mistakes
- Using the full-pipe hydraulic radius D/4 at part depth.
- Expecting exactly full-pipe capacity at y = D.
Assumptions and limits
- Uniform flow, constant Manning n.
References
- Manning's equation for a part-full circular section
Questions and answers
Why can a pipe carry more just below full?
Near the crown the wetted perimeter grows faster than the area, so the hydraulic radius and the discharge peak at about 94 % depth.
What depth should sewers be designed for?
Many authorities size sewers to run at 50–80 % of the diameter at peak flow, keeping space for air and surcharge.
What do the defaults represent?
An illustrative 600 mm concrete sewer (n 0.013) on a 0.4 % slope flowing 360 mm deep.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Chow, Open-Channel Hydraulics (McGraw-Hill, 1959), ch. 6