Worked example
Example: Illustrative: 3 m gate opened 0.4 m, 2 m upstream, 0.9 m tailwater. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Upstream depth | 2.0000 m |
| Gate opening | 0.40000 m |
| Gate width | 3.0000 m |
| Tailwater depth downstream (0 if unknown) | 0.90000 m |
| Contraction coefficient | 0.61000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Discharge coefficient (Swamee) | 0.54415 |
| Discharge (Swamee) | 4.0897 m³/s |
| Discharge from energy with C_c | 4.3282 m³/s |
| Depth at the vena contracta C_c a | 0.24400 m |
| Froude number at the vena contracta | 3.8224 |
| Sequent depth of the jump (free flow needs tailwater below this) | 1.2026 m |
Open this example in the calculator and change any input.
Formula
\(Q = C_d B a\sqrt{2gy_1}, \quad C_d = 0.611\left(\frac{y_1 - a}{y_1 + 15a}\right)^{0.072}\)
\(Q_E = C_c a B\sqrt{\frac{2gy_1}{1 + C_c a/y_1}}, \quad y_2' = \frac{y_2}{2}\left(\sqrt{1 + 8Fr_2^2} - 1\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(y_1\) | Upstream depth | m |
| \(a\) | Gate opening | m |
| \(B\) | Gate width | m |
| \(y_3\) | Tailwater depth downstream (0 if unknown) | m |
| \(C_c\) | Contraction coefficient | - |
| \(C_d\) | Discharge coefficient (Swamee) | - |
| \(Q\) | Discharge (Swamee) | m³/s |
| \(Q_E\) | Discharge from energy with C_c | m³/s |
| \(y_2\) | Depth at the vena contracta C_c a | m |
| \(Fr_2\) | Froude number at the vena contracta | - |
| \(y_{2}'\) | Sequent depth of the jump (free flow needs tailwater below this) | m |
Method and standards
Free-flow sluice gate discharge.
Where it is used
- Irrigation canal head regulators and cross regulators.
- Spillway and barrage gates, flumes in laboratories.
Common mistakes
- Using the free-flow equation for a drowned gate.
- Measuring the upstream depth too close to the gate.
Assumptions and limits
- Vertical sharp-edged gate, free flow, rectangular channel.
References
- Swamee's free-flow discharge coefficient; energy equation with contraction coefficient; momentum for the sequent depth
- Swamee
- Sluice-gate discharge equations
- J. Irrigation and Drainage Engineering 118(1)
- 1992
Questions and answers
When is the flow submerged?
When the tailwater is deeper than the sequent depth of the jet's hydraulic jump; the jump then drowns the gate and the discharge falls for the same upstream depth.
What contraction coefficient should I use?
About 0.61 for a sharp-edged vertical gate; radial (Tainter) gates have different values that depend on the lip angle.
What do the defaults represent?
An illustrative 3 m wide canal gate opened 0.4 m with 2 m of water upstream and 0.9 m tailwater.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Henderson, Open Channel Flow (Macmillan, 1966), sec. 6.6