Worked example
Example: Illustrative: K 12 h, X 0.2, dt 6 h, inflow 120 to 260, outflow 100 m3/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Storage (travel time) constant | 12.000 h |
| Weighting factor (0 to 0.5) | 0.20000 - |
| Routing time step | 6.0000 h |
| Inflow at the start of the step | 120.00 m³/s |
| Inflow at the end of the step | 260.00 m³/s |
| Outflow at the start of the step | 100.00 m³/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Coefficient on I₂ | 0.047619 |
| Coefficient on I₁ | 0.42857 |
| Coefficient on O₁ | 0.52381 |
| Outflow at the end of the step | 116.19 m³/s |
| Change in reach storage over the step | 1,769,143 m³ |
Open this example in the calculator and change any input.
Formula
\(C_0 = \frac{\Delta t - 2KX}{2K(1 - X) + \Delta t}, \quad C_1 = \frac{\Delta t + 2KX}{2K(1 - X) + \Delta t}, \quad C_2 = \frac{2K(1 - X) - \Delta t}{2K(1 - X) + \Delta t}\)
\(O_2 = C_0I_2 + C_1I_1 + C_2O_1\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(K\) | Storage (travel time) constant | s |
| \(X\) | Weighting factor (0 to 0.5) | - |
| \(\Delta t\) | Routing time step | s |
| \(I_1\) | Inflow at the start of the step | m³/s |
| \(I_2\) | Inflow at the end of the step | m³/s |
| \(O_1\) | Outflow at the start of the step | m³/s |
| \(C_0\) | Coefficient on I₂ | - |
| \(C_1\) | Coefficient on I₁ | - |
| \(C_2\) | Coefficient on O₁ | - |
| \(O_2\) | Outflow at the end of the step | m³/s |
| \(\Delta S\) | Change in reach storage over the step | m³ |
Method and standards
Muskingum linear storage routing.
Where it is used
- Flood forecasting along rivers.
- Design of channel reaches and detention.
Common mistakes
- Choosing a time step outside 2KX to 2K(1 − X).
- Using X above 0.5.
Assumptions and limits
- Linear storage, no lateral inflow.
References
- Muskingum hydrologic routing
Questions and answers
How are K and X found?
From observed inflow and outflow hydrographs of the reach: plot storage against XI + (1 − X)O for trial X until the loop collapses to a line of slope K. K is close to the travel time through the reach.
How do I route a whole hydrograph?
Apply O₂ = C₀I₂ + C₁I₁ + C₂O₁ step by step, using each step's outflow as the next O₁.
What do the defaults represent?
An illustrative reach with K = 12 h and X = 0.2 routed in 6-hour steps as the inflow rises from 120 to 260 m³/s.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Chow, Maidment and Mays, Applied Hydrology (McGraw-Hill, 1988), sec. 8.4