FireCADCalc

Swimming Pool Filtration: Turnover, Pump Flow and Filter Area

Recirculation flow of a swimming pool from its volume and turnover period, the sand filter area at a filtration rate and the number of turnovers per day.

Inputs

Examples: Illustrative 375 m3 poolPublic pool, 3 h, two filtersSpa, 30 minutes

Accepted: 1 to 100,000 m³
Accepted: 0.5 to 24 h
Accepted: 1 to 60 m/h
Accepted: 1 to 20

Results

The whole pool volume should pass through the filters in the turnover period: about 4–6 h for private and hotel pools, 2–4 h for busy public pools and 0.5–1 h for spas and children's pools. The pump flow is volume over turnover time; the filter area is that flow over the filtration rate (about 10–25 m/h for medium-rate sand filters, up to 50 m/h for high-rate). Size the pump for the filter, pipework and heater losses at that flow.

Recirculation flow62.500m³/h
Total filter area2.5000m²
Diameter of each filter1,784.1mm
Turnovers per day4.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 375 m3 pool. The inputs, in the units selected above:

InputValue
Pool volume375.00 m³
Turnover period6.0000 h
Filtration rate25.000 m/h
Number of filters1.0000 -

Applying the formula below gives:

ResultValue
Recirculation flow62.500 m³/h
Total filter area2.5000 m²
Diameter of each filter1,784.1 mm
Turnovers per day4.0000

Open this example in the calculator and change any input.

Formula

\(Q = \frac{V}{t_t}, \quad A = \frac{Q}{v_f}, \quad d = \sqrt{\frac{4A}{n\pi}}\)

Variables

Symbol Meaning SI unit
\(V\) Pool volume m³
\(t_t\) Turnover period s
\(v_f\) Filtration rate m/s
\(n\) Number of filters -
\(Q\) Recirculation flow m³/s
\(A\) Total filter area m²
\(d\) Diameter of each filter m
\(N_d\) Turnovers per day -

Method and standards

Pool filtration.

Where it is used

  • Hotel, club and public pools.
  • Checking pump and filter offers.

Common mistakes

  • Using high-rate filter speeds for medium-rate media.
  • Forgetting balancing-tank volume.

Assumptions and limits

  • Uniform circulation.

References

  • Turnover and filtration-rate sizing

Questions and answers

What pump flow for a 375 m³ pool with 6-hour turnover?

62.5 m³/h, with 2.5 m² of sand filter at 25 m/h.

How often should pool water turn over?

Every 4–6 hours for private pools, 2–4 hours for busy public pools.

What do the defaults represent?

An illustrative 25 m × 10 m × 1.5 m pool (375 m³), 6-hour turnover, one sand filter at 25 m/h.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.