Worked example
Example: Boiler feed pump 60 m³/h, 850 m, water 105 °C (955 kg/m³), pump 68 %, motor 95 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flow | 60.000 m³/h |
| Total head | 850.00 m |
| Liquid density at pumping temperature | 955.00 kg/m³ |
| Pump efficiency | 68.000 % |
| Motor efficiency | 95.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pump shaft power (brake power) | 195.11 kW |
| Electrical input power | 205.38 kW |
| Hydraulic power | 132.68 kW |
| Pressure rise across the pump | 7,960.5 kPa |
| Mass flow | 57,300 kg/h |
Open this example in the calculator and change any input.
Formula
\(P_h = \rho\,g\,Q\,H \qquad P_s = \frac{P_h}{\eta_p} \qquad P_e = \frac{P_s}{\eta_m} \qquad \Delta p = \rho\,g\,H \qquad \dot m = \rho\,Q\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | flow | m³/s |
| \(H\) | total head | m |
| \(\rho\) | liquid density at pumping temperature | kg/m³ |
| \(\eta_p\) | pump efficiency | – |
| \(\eta_m\) | motor efficiency | – |
| \(P_h\) | hydraulic power | W |
| \(P_s\) | pump shaft power | W |
| \(P_e\) | electrical input power | W |
| \(\Delta p\) | pressure rise across the pump | Pa |
| \(\dot m\) | mass flow | kg/s |
| \(g\) | standard gravity, 9.806 65 | m/s² |
Method and standards
Power definitions of ANSI/HI 1.6 and ISO 9906: pump output (hydraulic) power is the product of density, gravity, rate of flow and total head; pump efficiency is output power over shaft power.
Where it is used
- Motor sizing for feed, make-up, transfer and cooling water pumps.
- Energy audits: comparing measured power with the hydraulic duty.
- Estimating running cost of pumps.
Common mistakes
- Using the head in bar for a liquid of another density, or density 1000 kg/m³ for hot water.
- Using the efficiency at best efficiency point for an off-design duty.
- Selecting the motor at the shaft power without margin.
Assumptions and limits
- Density at the pumping temperature; use the water properties calculator for hot water.
- The pressure rise ρ g H equals the rise in static pressure only when the suction and discharge velocities and gauge heights are equal; otherwise it is the total-head equivalent.
- Coupling and gearbox losses are not included; divide the shaft power by the drive efficiency if there is one.
- Viscous liquids lower the pump efficiency and head (ANSI/HI 9.6.7); enter the corrected efficiency.
References
- ANSI/HI 1.6 (centrifugal pump tests, power definitions)
- ISO 9906
Questions and answers
How do I calculate pump power?
Hydraulic power = ρ·g·Q·H. A boiler feed pump delivering 60 m³/h of water at 105 °C (955 kg/m³) against 850 m gives 132.7 kW to the water; at 68 % pump efficiency the shaft power is 195 kW.
Why does hot water need less power for the same head?
Head is energy per unit weight, so for the same head and volume flow the power falls with density. But a boiler feed pump must reach a pressure, and for a given pressure rise the head needed is higher for hot water, so the power for the same volume flow is unchanged.
What motor should I choose?
The calculator gives the power absorbed at this duty. The motor rating must cover the pump's end-of-curve power or the margin of your standard (for example API 610 or the purchaser's specification).
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.