Worked example
Example: Gear pump 250 mL/rev, 600 rpm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Displacement per revolution | 0.25000 L |
| Speed | 600.00 rpm |
| Measured delivery | 8.5000 m³/h |
| Differential pressure | 10.000 bar |
| Shaft power | 3.2000 kW |
Applying the formula below gives:
| Result | Value |
|---|---|
| Theoretical flow | 9.0000 m³/h |
| Slip | 0.50000 m³/h |
| Volumetric efficiency | 94.444 % |
| Hydraulic power | 2.3611 kW |
| Overall efficiency | 73.785 % |
| Mechanical efficiency | 78.125 % |
Open this example in the calculator and change any input.
Formula
\(Q_t = V_dN, \quad S = Q_t - Q, \quad \eta_v = \frac{Q}{Q_t}, \quad \eta_o = \frac{Q\Delta p}{P_s}, \quad \eta_m = \frac{\eta_o}{\eta_v}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_d\) | Displacement per revolution | m³ |
| \(N\) | Speed | 1/s |
| \(Q\) | Measured delivery | m³/s |
| \(\Delta p\) | Differential pressure | Pa |
| \(P_s\) | Shaft power | W |
| \(Q_t\) | Theoretical flow | m³/s |
| \(S\) | Slip | m³/s |
| \(\eta_v\) | Volumetric efficiency | - |
| \(P_h\) | Hydraulic power | W |
| \(\eta_o\) | Overall efficiency | - |
| \(\eta_m\) | Mechanical efficiency | - |
Method and standards
Definitions.
Where it is used
- Dosing, fuel oil and molasses pumps.
- Condition monitoring of gear and screw pumps.
Common mistakes
- Using nameplate displacement for a worn pump.
- Measuring flow at a different pressure from the power.
Assumptions and limits
- Steady test conditions.
References
- Positive displacement pump definitions (Perry's Chemical Engineers' Handbook, 9th ed. (McGraw-Hill, 2019), sec. 10, positive displacement pumps)
Questions and answers
What is slip?
Liquid leaking back through clearances from discharge to suction; delivery is displacement minus slip.
Why does slip fall with viscosity?
Thicker liquid leaks less through the same clearances; gear pumps on thin liquids show high slip.
What do the defaults give?
250 mL/rev at 600 rpm, 8.5 m³/h at 10 bar on 3.2 kW: 94 % volumetric, 74 % overall.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.