FireCADCalc

Reciprocating Pump Acceleration Head (NPSH)

Acceleration head of the suction line of a reciprocating pump from line length, velocity, speed, pump type and liquid factor, to add to friction in the NPSH check.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textilePump

Inputs

Examples: Ganapathy: triplex, 3 in line 8 ftGanapathy: triplex, 2 in line 18 ft

Results

Add the acceleration head to friction losses when checking NPSH available; a suction pulsation dampener can cut L to almost nothing.

Mean velocity in the suction line0.47621m/s
Acceleration head2.0096m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy: triplex, 3 in line 8 ft. The inputs, in the units selected above:

InputValue
Suction line length2.4384 m
Average flow8.1765 m³/h
Suction line inner diameter77.927 mm
Pump speed360.00 rpm
Pump typeTriplex (0.066)
Liquid factorDeaerated water (1.4)

Applying the formula below gives:

ResultValue
Mean velocity in the suction line0.47621 m/s
Acceleration head2.0096 m

Open this example in the calculator and change any input.

Formula

\(H_a = \frac{L\,V\,N\,C}{K\,g}\)

Variables

Symbol Meaning SI unit
\(L\) Suction line length m
\(Q\) Average flow m³/s
\(d\) Suction line inner diameter m
\(N\) Pump speed 1/s
\(C\) Pump type -
\(K\) Liquid factor -
\(V\) Mean velocity in the suction line m/s
\(H_a\) Acceleration head m

Method and standards

Ganapathy's Q5.17 (N in rpm; any consistent length units).

Where it is used

  • Boiler chemical dosing and high-pressure pumps.
  • Reciprocating feed pumps.

Common mistakes

  • Using the developed length.
  • Forgetting each line segment separately.

Assumptions and limits

  • Rigid suction line; sum segments of different size.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q5.17 (acceleration head; constants C and K)

Questions and answers

Why an acceleration head?

The liquid column in the suction line must be accelerated on every stroke; without enough head it separates and the pump knocks.

What do C and K mean?

C reflects the flow pulsation of the pump type; K the liquid's compressibility.

What does Ganapathy's example give?

A triplex at 360 rpm, 36 gpm, with 8 ft of 3 in line (3.068 in bore) gives 6.6 ft (2.01 m); the 18 ft of 2 in line (2.067 in bore) adds 32.7 ft (9.96 m). The book prints 6.7 ft and 32.9 ft; the small difference is rounding in its working.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.