FireCADCalc

Liquid Jet Pump (Eductor): Flow Ratio, Head Ratio and Efficiency

Flow ratio, head ratio and efficiency of a liquid jet pump or eductor from motive, suction and discharge heads and the motive and entrained flows.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 10 m³/h motive at 60 m, lifting 8 m³/hTank mixing eductor

Results

Same fluid for motive and suction. Jet pumps are simple and robust but rarely exceed 30–35 % efficiency.

Flow ratio Q_s/Q_m0.80000
Head ratio (H_d − H_s)/(H_m − H_d)0.24000
Efficiency M·N19.200%
Discharge flow18.000m³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 m³/h motive at 60 m, lifting 8 m³/h. The inputs, in the units selected above:

InputValue
Motive flow10.000 m³/h
Suction (entrained) flow8.0000 m³/h
Motive head at the nozzle60.000 m
Suction head-2.0000 m
Discharge head10.000 m

Applying the formula below gives:

ResultValue
Flow ratio Q_s/Q_m0.80000
Head ratio (H_d − H_s)/(H_m − H_d)0.24000
Efficiency M·N19.200 %
Discharge flow18.000 m³/h

Open this example in the calculator and change any input.

Formula

\(M = \frac{Q_s}{Q_m}, \quad N = \frac{H_d - H_s}{H_m - H_d}, \quad \eta = MN\)

Variables

Symbol Meaning SI unit
\(Q_m\) Motive flow m³/s
\(Q_s\) Suction (entrained) flow m³/s
\(H_m\) Motive head at the nozzle m
\(H_s\) Suction head m
\(H_d\) Discharge head m
\(M\) Flow ratio Q_s/Q_m -
\(N\) Head ratio (H_d − H_s)/(H_m − H_d) -
\(\eta\) Efficiency M·N -
\(Q_d\) Discharge flow m³/s

Method and standards

Energy balance definitions.

Where it is used

  • Tank mixing eductors.
  • Sump and well jet pumps.

Common mistakes

  • Using gauge pressures at different levels without converting to heads.
  • Ignoring nozzle wear.

Assumptions and limits

  • Same liquid; steady.
  • H_m, H_s and H_d are total heads (pressure plus velocity head) at the motive inlet, suction and discharge connections, on one common datum.
  • Efficiencies above 35 %, and above 100 %, are flagged.

References

  • Jet pump head and flow ratios and efficiency η = MN (definitions; Karassik et al., Pump Handbook)

Questions and answers

Why so inefficient?

Mixing a fast jet with slow liquid destroys kinetic energy as turbulence; the best designs reach about a third.

Why use them?

No moving parts: tank mixing, priming, sump emptying, handling solids or corrosive liquids.

What do the defaults represent?

An eductor driven by 10 m³/h at 60 m head lifting 8 m³/h from 2 m below to a 10 m discharge.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.