Worked example
Example: 2 950 rpm, 100 m³/h, NPSHr 4 m, NPSHa 6 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Speed | 2,950.0 rpm |
| Flow at best efficiency (per impeller eye) | 100.00 m³/h |
| NPSH required | 4.0000 m |
| NPSH available | 6.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Suction specific speed (rpm, m³/s, m) | 173.83 |
| Suction specific speed (US units: rpm, gpm, ft) | 8,977.5 |
| NPSH margin NPSH_a − NPSH_r | 2.0000 m |
| NPSH margin ratio | 1.5000 |
Open this example in the calculator and change any input.
Formula
\(N_{ss} = \frac{n\sqrt{Q}}{NPSH_r^{0.75}}, \quad \text{margin} = NPSH_a - NPSH_r\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(n\) | Speed | 1/s |
| \(Q\) | Flow at best efficiency (per impeller eye) | m³/s |
| \(NPSH_r\) | NPSH required | m |
| \(NPSH_a\) | NPSH available | m |
| \(N_{ss}\) | Suction specific speed (rpm, m³/s, m) | - |
| \(N_{ss,US}\) | Suction specific speed (US units: rpm, gpm, ft) | - |
| \(\Delta\) | NPSH margin NPSH_a − NPSH_r | m |
| \(NPSH_a/NPSH_r\) | NPSH margin ratio | - |
Method and standards
Definitions.
Where it is used
- Pump selection and suction troubleshooting.
- Specification checks.
Common mistakes
- Total flow for double suction.
- Mixing unit systems.
Assumptions and limits
- Values at best efficiency point.
References
- Suction specific speed definition N_ss = n √Q / NPSH_r^0.75 (Hydraulic Institute terminology)
Questions and answers
What does a high N_ss mean?
A pump designed for low NPSH, often with a narrow stable operating range.
Which flow for a double-suction pump?
Half the flow: per impeller eye.
What margin is enough?
It depends on the service; many guides ask for a ratio of 1.1 to 1.5 or more.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.