FireCADCalc

Pump Flow Estimate from Measured Power and Head

Estimated pump flow from the measured electrical power and differential head with assumed pump and motor efficiencies, for pumps without a flowmeter.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 30 kW input at 35 m110 kW at 80 m5.5 kW at 20 m, light oil 850

Results

An estimate: the result is only as good as the efficiencies. Iterate with the pump curve: read η at the estimated flow and recalculate.

Shaft power27.900kW
Estimated flow211.12m³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 30 kW input at 35 m. The inputs, in the units selected above:

InputValue
Measured electrical input30.000 kW
Measured differential head35.000 m
Pump efficiency (from the curve at the estimated duty)72.000 %
Motor efficiency at this load93.000 %
Liquid density998.00 kg/m³

Applying the formula below gives:

ResultValue
Shaft power27.900 kW
Estimated flow211.12 m³/h

Open this example in the calculator and change any input.

Formula

\(Q = \frac{P_e\, \eta_m\, \eta_p}{\rho g H}\)

Variables

Symbol Meaning SI unit
\(P_e\) Measured electrical input W
\(H\) Measured differential head m
\(\eta_p\) Pump efficiency (from the curve at the estimated duty) -
\(\eta_m\) Motor efficiency at this load -
\(\rho\) Liquid density kg/m³
\(P_s\) Shaft power W
\(Q\) Estimated flow m³/s

Method and standards

Energy balance reversed.

Where it is used

  • Pump surveys without meters.
  • Troubleshooting.

Common mistakes

  • Using nameplate efficiency at part load.
  • Head from suction gauge only.

Assumptions and limits

  • Efficiencies known.

References

  • Q = P_e η_m η_p / (ρ g H)

Questions and answers

30 kW input at 35 m head?

About 211 m³/h with 72 % and 93 % efficiencies.

How accurate?

Only as good as the efficiencies: the flow is proportional to η_p η_m, so a 5-point error in pump efficiency at 72 % changes the flow by about 7 %.

Better method?

A clamp-on ultrasonic flowmeter.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.