Worked example
Example: Speed 2 950 to 2 400 rpm (VFD). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flow | 100.00 m³/h |
| Head | 80.000 m |
| Shaft power | 30.000 kW |
| Speed | 2,950.0 rpm |
| Impeller diameter | 250.00 mm |
| New speed | 2,400.0 rpm |
| New impeller diameter (same as above = no trim) | 250.00 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| New flow | 81.356 m³/h |
| New head | 52.950 m |
| New shaft power | 16.154 kW |
| Combined ratio N₂D₂ / N₁D₁ | 0.81356 |
Open this example in the calculator and change any input.
Formula
\(k = \frac{N_2\,D_2}{N_1\,D_1} \qquad Q_2 = k\,Q_1 \qquad H_2 = k^2\,H_1 \qquad P_2 = k^3\,P_1\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_1\) | known flow | m³/s |
| \(H_1\) | known head | m |
| \(P_1\) | known shaft power | W |
| \(N_1\) | known speed | 1/s |
| \(D_1\) | known impeller diameter | m |
| \(N_2\) | new speed | 1/s |
| \(D_2\) | new impeller diameter | m |
| \(Q_2\) | new flow | m³/s |
| \(H_2\) | new head | m |
| \(P_2\) | new shaft power | W |
| \(k\) | combined ratio of speed and diameter | – |
Method and standards
The affinity rules as given in ANSI/HI 1.3 for a centrifugal pump: corresponding points on the curves at two speeds, or with a trimmed impeller in the same casing, have the same efficiency and scale with the ratio of speed times diameter.
Where it is used
- Predicting flow, head and power after a speed change or VFD.
- Impeller trimming estimates.
- Energy-saving studies of throttled pumps.
Common mistakes
- Applying the laws to a system with large static head: the operating point does not scale.
- Using them for large impeller trims beyond about 10 %.
- Forgetting that efficiency changes off the best efficiency point.
Assumptions and limits
- Corresponding points only: the result is a point on the new pump curve, not the new operating point; that is where the new curve meets the system curve.
- Efficiency unchanged; valid for moderate speed changes and trims up to about 20 %. No efficiency scaling (such as Moody's) is applied, and no warning is given for large speed changes: below about half speed the efficiency falls and the power is higher than k³ P₁.
- Same liquid; NPSH required scales roughly with speed squared and must be checked separately.
References
- ANSI/HI 1.3 (centrifugal pump application, affinity rules)
Questions and answers
What are the pump affinity laws?
Flow varies with speed, head with speed squared and power with speed cubed. Slowing a pump from 2 950 to 2 400 rpm gives 81 % of the flow, 66 % of the head and 54 % of the power.
Do the same laws apply to trimming the impeller?
Approximately, with the diameter ratio in place of the speed ratio, for trims up to about 10–20 %. Trimming also changes the impeller geometry, so real pumps lose slightly more head; makers apply a correction.
Will a VFD always save the cube of the speed?
Only when the system is all friction. A boiler feed pump works against a high static pressure, so its operating point does not follow the affinity parabola and the saving is much smaller.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.