FireCADCalc

Settling Tank: Stokes Velocity and Overflow Rate

Settling velocity of a particle by Stokes' law and the surface (overflow) rate of a settling tank, with the area needed to remove that particle size.

Sugar mill and cogenerationRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 50 µm sand20 µm ash in warm water

Results

Stokes settling velocity8.1003m/h
Particle Reynolds number0.11228
Overflow rate Q/A1.2500m/h
Area to settle this particle6.1726m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 µm sand. The inputs, in the units selected above:

InputValue
Flow to the tank50.000 m³/h
Tank surface area40.000 m²
Particle diameter50.000 µm
Particle density2,650.0 kg/m³
Liquid density998.00 kg/m³
Liquid viscosity0.001000 Pa·s

Applying the formula below gives:

ResultValue
Stokes settling velocity8.1003 m/h
Particle Reynolds number0.11228
Overflow rate Q/A1.2500 m/h
Area to settle this particle6.1726 m²

Open this example in the calculator and change any input.

Formula

\(v_s = \frac{g(\rho_p - \rho_l)d^2}{18\mu}, \quad v_o = \frac{\dot V}{A}, \quad A_n = \frac{\dot V}{v_s}\)

Variables

Symbol Meaning SI unit
\(\dot V\) Flow to the tank m³/s
\(A\) Tank surface area m²
\(d\) Particle diameter m
\(\rho_p\) Particle density kg/m³
\(\rho_l\) Liquid density kg/m³
\(\mu\) Liquid viscosity Pa·s
\(v_s\) Stokes settling velocity m/s
\(Re_p\) Particle Reynolds number -
\(v_o\) Overflow rate Q/A m/s
\(A_n\) Area to settle this particle m²

Method and standards

Stokes and Hazen.

Where it is used

  • Clarifiers, settling pits and ash ponds.
  • Cooling tower basins.

Common mistakes

  • Stokes beyond its range.
  • Ignoring short-circuiting.

Assumptions and limits

  • Spherical, discrete particles.

References

  • Stokes' law v = g(ρ_p − ρ)d²/(18μ); ideal settling basin (Hazen): removal when v_s ≥ Q/A

Questions and answers

50 µm sand in water?

About 8.1 m/h; 50 m³/h needs 6.2 m² of surface.

Why does depth not matter?

In an ideal basin removal depends on surface area, not depth.

Flocculated solids?

Use measured settling velocities from a jar or column test.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.