Worked example
Example: 50 µm sand. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flow to the tank | 50.000 m³/h |
| Tank surface area | 40.000 m² |
| Particle diameter | 50.000 µm |
| Particle density | 2,650.0 kg/m³ |
| Liquid density | 998.00 kg/m³ |
| Liquid viscosity | 0.001000 Pa·s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Stokes settling velocity | 8.1003 m/h |
| Particle Reynolds number | 0.11228 |
| Overflow rate Q/A | 1.2500 m/h |
| Area to settle this particle | 6.1726 m² |
Open this example in the calculator and change any input.
Formula
\(v_s = \frac{g(\rho_p - \rho_l)d^2}{18\mu}, \quad v_o = \frac{\dot V}{A}, \quad A_n = \frac{\dot V}{v_s}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V\) | Flow to the tank | m³/s |
| \(A\) | Tank surface area | m² |
| \(d\) | Particle diameter | m |
| \(\rho_p\) | Particle density | kg/m³ |
| \(\rho_l\) | Liquid density | kg/m³ |
| \(\mu\) | Liquid viscosity | Pa·s |
| \(v_s\) | Stokes settling velocity | m/s |
| \(Re_p\) | Particle Reynolds number | - |
| \(v_o\) | Overflow rate Q/A | m/s |
| \(A_n\) | Area to settle this particle | m² |
Method and standards
Stokes and Hazen.
Where it is used
- Clarifiers, settling pits and ash ponds.
- Cooling tower basins.
Common mistakes
- Stokes beyond its range.
- Ignoring short-circuiting.
Assumptions and limits
- Spherical, discrete particles.
References
- Stokes' law v = g(ρ_p − ρ)d²/(18μ); ideal settling basin (Hazen): removal when v_s ≥ Q/A
Questions and answers
50 µm sand in water?
About 8.1 m/h; 50 m³/h needs 6.2 m² of surface.
Why does depth not matter?
In an ideal basin removal depends on surface area, not depth.
Flocculated solids?
Use measured settling velocities from a jar or column test.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.