Bubble and Dew Point of a Binary Mixture (Raoult's Law)

Bubble-point and dew-point temperatures of an ideal two-component liquid mixture at a pressure, with the first vapour and first liquid compositions, from Antoine constants.

Sugar mill and cogenerationRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Benzene–toluene 50/50 at 1 atmBenzene–toluene 30/70 at 1 atmBenzene–toluene 70/30 at 0.8 bar

Component 1 (Antoine constants in log10(p/bar) = A − B/(T/K + C))

Defaults: benzene, 287.7–354.07 K, NIST Chemistry WebBook (Williamham et al., 1945).

Component 2 (Antoine constants in log10(p/bar) = A − B/(T/K + C))

Defaults: toluene, 308.52–384.66 K, NIST Chemistry WebBook (Williamham et al., 1945).

Results

Ideal liquid and ideal gas (Raoult's law): good for close relatives such as benzene–toluene, wrong for water with organics or azeotropes.

Check that both temperatures lie inside the range of each set of Antoine constants; outside it the vapour pressures are extrapolated (the default benzene set is for 287.7–354.07 K, so the default case is an extrapolation).

Bubble-point temperature98.461°C
First vapour: mole fraction of component 151.106%
Dew-point temperature104.00°C
First liquid: mole fraction of component 115.175%
Relative volatility at the bubble point2.4389

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Benzene–toluene 50/50 at 1 atm. The inputs, in the units selected above:

InputValue
Pressure (absolute)1.0132 bar
Mole fraction of component 1 (the lighter one)50.000 %
Component 1: A4.0181 -
Component 1: B1,203.8 -
Component 1: C-53.226 -
Component 2: A4.0783 -
Component 2: B1,343.9 -
Component 2: C-53.773 -

Applying the formula below gives:

ResultValue
Bubble-point temperature92.116 °C
First vapour: mole fraction of component 171.358 %
Dew-point temperature98.774 °C
First liquid: mole fraction of component 129.100 %
Relative volatility at the bubble point2.4914

Open this example in the calculator and change any input.

Formula

\(\sum x_i\, p_i^{sat}(T_{bub}) = p, \quad \sum \frac{y_i}{p_i^{sat}(T_{dew})} = \frac{1}{p}\)

\(\log_{10} p^{sat} = A - \frac{B}{T + C}\)

Variables

Symbol Meaning SI unit
\(p\) Pressure (absolute) Pa
\(z_1\) Mole fraction of component 1 (the lighter one) -
\(A_1\) Component 1: A -
\(B_1\) Component 1: B -
\(C_1\) Component 1: C -
\(A_2\) Component 2: A -
\(B_2\) Component 2: B -
\(C_2\) Component 2: C -
\(T_{bub}\) Bubble-point temperature K
\(y_1\) First vapour: mole fraction of component 1 -
\(T_{dew}\) Dew-point temperature K
\(x_1\) First liquid: mole fraction of component 1 -
\(\alpha_{12}\) Relative volatility at the bubble point -

Method and standards

Raoult's law with Antoine vapour pressures, solved for temperature.

Where it is used

  • Distillation column design.
  • Flash calculations.
  • Chemical engineering examinations.

Common mistakes

  • Mixing Antoine units.
  • Using outside the constants' range.

Assumptions and limits

  • Ideal liquid and vapour.
  • Antoine constants in the bar and K form; a result below absolute zero (constants entered in the mmHg and °C form) is rejected.
  • Each set of constants holds only over its temperature range; the page does not check it. The default benzene set ends at 354.07 K, so the default case is extrapolated.

References

  • Raoult's law (ideal solution)
  • NIST Chemistry WebBook Antoine parameters

Questions and answers

Where does a 50/50 benzene–toluene liquid boil at 1 atm?

92.1 °C, with a first vapour of 71.4 % benzene. It is all vapour at the dew point, 98.8 °C.

What is relative volatility?

p₁sat/p₂sat: about 2.5 here, used in the Fenske equation.

When is Raoult's law wrong?

For dissimilar liquids (water with organics) and azeotropes.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators