Worked example
Example: α 2.5, 40 % feed, 95/5 %, R = 1.5 Rmin. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Relative volatility | 2.5000 - |
| Light component in the feed (mole fraction) | 40.000 % |
| Light component in the distillate | 95.000 % |
| Light component in the bottoms | 5.0000 % |
| Feed condition q | 1.0000 - |
| Reflux as a multiple of the minimum | 1.5000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Minimum reflux ratio | 1.4444 |
| Reflux ratio | 2.1667 |
| Theoretical stages (reboiler = 1) | 11.722 |
| Optimum feed stage from the top | 6.0000 |
Open this example in the calculator and change any input.
Formula
\(y^* = \frac{\alpha x}{1 + (\alpha - 1)x}, \quad y = \frac{R}{R+1}x + \frac{x_D}{R+1}, \quad R_{min} = \frac{x_D - y_p}{y_p - x_p}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\alpha\) | Relative volatility | - |
| \(x_F\) | Light component in the feed (mole fraction) | - |
| \(x_D\) | Light component in the distillate | - |
| \(x_B\) | Light component in the bottoms | - |
| \(q\) | Feed condition q | - |
| \(R/R_{min}\) | Reflux as a multiple of the minimum | - |
| \(R_{min}\) | Minimum reflux ratio | - |
| \(R\) | Reflux ratio | - |
| \(N\) | Theoretical stages (reboiler = 1) | - |
| \(N_F\) | Optimum feed stage from the top | - |
Method and standards
Stage-by-stage stepping from the top with constant molar overflow.
Where it is used
- Column design and debottlenecking.
- Teaching distillation.
Common mistakes
- Using α at one end only when it varies.
- Counting the reboiler twice.
Assumptions and limits
- Constant α and molar overflow; total condenser.
- If the stepping reaches x_B without crossing the operating-line intersection, the feed stage is not shown and a note says so.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 13 (distillation)
- McCabe–Thiele method
- Mass Transfer Tutorial: Distillation (McCabe–Thiele example)
Questions and answers
Where is the feed stage?
The stage where stepping first crosses the intersection of the operating lines; switching there gives the fewest stages.
Why fractional stages?
The last step rarely lands on x_B; the fraction shows how much of a stage is needed.
Is the reboiler a stage?
Yes, a partial reboiler is one equilibrium stage, counted in N.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.