FireCADCalc

McCabe–Thiele Stages with Constant Relative Volatility

Theoretical stages, optimum feed stage and minimum reflux of a binary distillation with constant relative volatility, by stepping off McCabe–Thiele stages.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: α 2.5, 40 % feed, 95/5 %, R = 1.5 Rminα 2.0, part-vapour feed q 0.5

Results

The last stage counted as a fraction is the share of a stage needed to reach x_B; the reboiler is the last stage.

Minimum reflux ratio2.2976
Reflux ratio2.9869
Theoretical stages (reboiler = 1)21.124
Optimum feed stage from the top11.000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: α 2.5, 40 % feed, 95/5 %, R = 1.5 Rmin. The inputs, in the units selected above:

InputValue
Relative volatility2.5000 -
Light component in the feed (mole fraction)40.000 %
Light component in the distillate95.000 %
Light component in the bottoms5.0000 %
Feed condition q1.0000 -
Reflux as a multiple of the minimum1.5000 -

Applying the formula below gives:

ResultValue
Minimum reflux ratio1.4444
Reflux ratio2.1667
Theoretical stages (reboiler = 1)11.722
Optimum feed stage from the top6.0000

Open this example in the calculator and change any input.

Formula

\(y^* = \frac{\alpha x}{1 + (\alpha - 1)x}, \quad y = \frac{R}{R+1}x + \frac{x_D}{R+1}, \quad R_{min} = \frac{x_D - y_p}{y_p - x_p}\)

Variables

Symbol Meaning SI unit
\(\alpha\) Relative volatility -
\(x_F\) Light component in the feed (mole fraction) -
\(x_D\) Light component in the distillate -
\(x_B\) Light component in the bottoms -
\(q\) Feed condition q -
\(R/R_{min}\) Reflux as a multiple of the minimum -
\(R_{min}\) Minimum reflux ratio -
\(R\) Reflux ratio -
\(N\) Theoretical stages (reboiler = 1) -
\(N_F\) Optimum feed stage from the top -

Method and standards

Stage-by-stage stepping from the top with constant molar overflow.

Where it is used

  • Column design and debottlenecking.
  • Teaching distillation.

Common mistakes

  • Using α at one end only when it varies.
  • Counting the reboiler twice.

Assumptions and limits

  • Constant α and molar overflow; total condenser.
  • If the stepping reaches x_B without crossing the operating-line intersection, the feed stage is not shown and a note says so.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 13 (distillation)
  • McCabe–Thiele method
  • Mass Transfer Tutorial: Distillation (McCabe–Thiele example)

Questions and answers

Where is the feed stage?

The stage where stepping first crosses the intersection of the operating lines; switching there gives the fewest stages.

Why fractional stages?

The last step rarely lands on x_B; the fraction shows how much of a stage is needed.

Is the reboiler a stage?

Yes, a partial reboiler is one equilibrium stage, counted in N.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.