FireCADCalc

Steam or Gas Stripping Stages (Kremser)

Theoretical stages of a counter-current stripper with a straight equilibrium line from the liquid inlet and outlet and the stripping gas, by the Kremser equation.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: Steam stripper S = 1.5Air stripper with some solute in air

Results

Stripping factor mV/L1.5000
Theoretical stages8.6971
Fraction stripped99.000%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Steam stripper S = 1.5. The inputs, in the units selected above:

InputValue
Solute in the liquid entering (mole fraction)0.10000 %
Solute in the liquid leaving0.001000 %
Solute in the stripping gas entering0 %
Equilibrium slope y = mx30.000 -
Stripping gas to liquid molar ratio0.050000 -

Applying the formula below gives:

ResultValue
Stripping factor mV/L1.5000
Theoretical stages8.6971
Fraction stripped99.000 %

Open this example in the calculator and change any input.

Formula

\(\frac{x_{in} - x_{out}}{x_{in} - y_{in}/m} = \frac{S^{N+1} - S}{S^{N+1} - 1}, \quad S = \frac{mV}{L}\)

Variables

Symbol Meaning SI unit
\(x_{in}\) Solute in the liquid entering (mole fraction) -
\(x_{out}\) Solute in the liquid leaving -
\(y_{in}\) Solute in the stripping gas entering -
\(m\) Equilibrium slope y = mx -
\(V/L\) Stripping gas to liquid molar ratio -
\(S\) Stripping factor mV/L -
\(N\) Theoretical stages -
\(\phi_S\) Fraction stripped -

Method and standards

Kremser stripping form solved for N.

Where it is used

  • Sour water and volatile organic stripping.
  • Deaerators and CO₂ strippers.

Common mistakes

  • Using the absorption factor.
  • Ignoring solute in the gas.

Assumptions and limits

  • Dilute; straight equilibrium; isothermal.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 13 (distillation)
  • Kremser equation for strippers

Questions and answers

What stripping factor is needed?

S above 1; around 1.4–2 gives a reasonable number of stages.

Why does the inlet gas matter?

Solute in the stripping gas sets a floor x = y_in/m below which the liquid cannot be stripped.

Is this the absorber equation turned round?

Yes, with A replaced by S = mV/L and liquid and gas swapped.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.