FireCADCalc

Multiple-Effect Evaporator Steam Consumption and Economy

Steam needed and steam economy of a forward-feed multiple-effect evaporator, from feed, concentrations, number of effects and steam and last-effect pressures.

Sugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Condenser and cooling tower

Inputs

Examples: Triple effect, 10 t/h from 5 % to 50 %, 2 bar(a) steam, 0.15 bar(a)Sugar juice quintuple, 50 t/h from 15 % to 65 %, 2.5 bar(a), 0.2 bar(a)Milk double effect, 5 t/h from 12 % to 45 %, 1.5 bar(a), 0.25 bar(a)

Results

Equal temperature drops, no boiling-point rise and no heat losses: real economies are a little lower.

Water evaporated9.0000t/h
Heating steam needed3.5951t/h
Steam economy (kg water per kg steam)2.5034kg/kg
Vapour from the last effect to the condenser3.1187t/h
Boiling temperature in the first effect98.131°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Triple effect, 10 t/h from 5 % to 50 %, 2 bar(a) steam, 0.15 bar(a). The inputs, in the units selected above:

InputValue
Feed flow10.000 t/h
Solids in the feed5.0000 %
Solids in the product50.000 %
Number of effects3
Heating steam pressure (absolute, saturated)2.0000 bar
Pressure in the last effect (absolute)0.15000 bar
Feed temperature60.000 °C
Specific heat of the liquor3.9000 kJ/(kg·K)

Applying the formula below gives:

ResultValue
Water evaporated9.0000 t/h
Heating steam needed3.5951 t/h
Steam economy (kg water per kg steam)2.5034 kg/kg
Vapour from the last effect to the condenser3.1187 t/h
Boiling temperature in the first effect98.131 °C

Open this example in the calculator and change any input.

Formula

\(E = F \left(1 - \frac{x_f}{x_p}\right)\)

\(S\, h_{fg}(T_s) + F c_p (T_f - T_1) = V_1 h_{fg}(T_1)\)

\(V_{i-1} h_{fg}(T_{i-1}) + L_{i-1} c_p (T_{i-1} - T_i) = V_i h_{fg}(T_i)\)

\(\sum V_i = E\)

Variables

Symbol Meaning SI unit
\(F\) feed flow kg/s
\(x_f\) solids in the feed -
\(x_p\) solids in the product -
\(N\) number of effects -
\(p_s\) heating steam pressure Pa
\(p_N\) last-effect pressure Pa
\(T_f\) feed temperature K
\(c_p\) liquor specific heat J/(kg·K)
\(T_s\) heating steam saturation temperature K
\(T_i\) boiling temperature in effect i K
\(T_1\) boiling temperature in the first effect K
\(h_{fg}\) latent heat of water J/kg
\(V_i\) vapour from effect i kg/s
\(L_i\) liquor leaving effect i kg/s
\(E\) water evaporated kg/s
\(S\) heating steam kg/s
\(E / S\) steam economy kg/kg
\(V_N\) vapour to the condenser kg/s

Method and standards

Forward feed: liquor flows from the first to the last effect with the vapour. Boiling temperatures fall in equal steps from the steam to the last-effect saturation temperature; each effect is heated by the previous effect's vapour, condensing at its saturation temperature (latent heats from IAPWS-IF97). The balances are linear in the steam flow, which is solved so the total evaporation matches.

Where it is used

  • Estimating steam demand for a sugar, dairy or effluent evaporator.
  • Comparing the gain from adding an effect.
  • Sizing the condenser for the last-effect vapour.

Common mistakes

  • Ignoring boiling-point rise in strong liquors (it reduces the useful temperature drop).
  • Using gauge pressure for the last effect: it is under vacuum, enter absolute.
  • Forgetting that a cold feed costs extra steam in the first effect.

Assumptions and limits

  • No boiling-point rise and no heat losses. For strong liquors (such as a 50 % solids product) the boiling-point rise eats into the temperature drops and the real economy is noticeably lower than shown.
  • Equal temperature drops per effect; liquor specific heat constant.
  • Forward feed; vapour bleeds to other users not included.

References

  • Effect-by-effect energy balance
  • IAPWS-IF97 latent heats

Questions and answers

What steam economy does a triple effect give?

About 2.5 kg of water evaporated per kg of steam in the example (10 t/h from 5 % to 50 %, steam at 2 bar(a), last effect 0.15 bar(a)).

Why is the economy below the number of effects?

Latent heat rises as pressure falls, the feed must be heated to boiling in the first effect, and each effect's vapour only just evaporates its own weight.

How much water must be evaporated?

E = F (1 − x_f/x_p): concentrating 10 t/h from 5 % to 50 % solids removes 9 t/h of water.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.